SPECIFICATIONS AND LIMITATIONS

2-F70MDV-342 | 2-F70MDV-350 | 2-F70MDV-364  

SPECIFICATIONS AND LIMITATIONS

2-F70MDV-342 | 2-F70MDV-350 | 2-F70MDV-364  

Total Grain Capacity: 2-F70MDV-342 / ET42H
1.32 cubic foot of high capacity cation
resin

Efficiency**

23,700 @ 5.3 lbs. of salt 
40,500 @ 11.9 lbs. of salt
43,200 @ 13.7 lbs. of salt
45,700 @ 19.8 lbs. of salt 
4,490 grains/lb of salt @ 5.3 lbs. of salt

Total Grain Capacity: 2-F70MDV-350 / ET50H
1.56 cubic foot of high capacity cation
resin

Efficiency**

28,000 @ 6.2 lbs. of salt 
47,800 @ 14.0 lbs. of salt
51,000 @ 16.2 lbs. of salt
54,100 @ 23.4 lbs. of salt
4.490 grains/lb of salt @ 6.2 lbs. of salt

Total Grain Capacity: 2-F70MDV-364 / ET64H
2.0 cubic foot of high capacity cation
resin

Efficiency**

35,900 @ 8.0 lbs. of salt 
61,300 @ 18.0 lbs. of salt
65,400 @ 20.8 lbs. of salt
69,300 @ 30.0 lbs. of salt
4,490 grains/lb of salt @ 8.0 lbs. of salt

Maximum Water Hardness

24-60 Grains Per Gallon

Maximum Ferrous Iron (depending on type of Iron)

1-10 PPMS

Minimum Ph

7

Regeneration Time

Approximately 80 – 120 Minutes

Water consumed during regeneration:
                                     2-F70MDV-342 / ET42H
                                     2-F70MDV-350 / ET50H
                                     2-F70MDV-364 / ET64H

77 gallons
90 gallons
116 gallons

Water Pressure

40 Min. –100 Max. PSI 85 psi day time pressure

Service Flow Rates:     2-F70MDV-342 / ET42H
                                     2-F70MDV-350 / ET50H
                                     2-F70MDV-364 / ET64H

13.7 gpm @ 15 psi pressure drop
16.0 gpm @ 15 psi pressure drop
18.6 gpm @ 15 psi pressure drop

Maximum flow rate to drain during regeneration:
                                     2-F70MDV-342 / ET42H
                                     2-F70MDV-350 / ET50H
                                     2-F70MDV-364 / ET64H

2.0 GPM
2.4 GPM
3.5 GPM

Temperature

Air : 40

°

  to 140

°

 F         Water : 40° to 110°F

Bypass Valve Size

1” or 1 1/4”

Drain Line Size

1/2” (under 20’ run and lower than 10’ vertical at 60 PSI) 
3/4” (over 20’ run or over 10’ high, or over 7GPM backwash 
rates)

Electrical Requirements

*Continuous 110 Volt, 60 Cycles/12volt/24volt

System Dimensions:
Media Tank and Valve: 2-F70MDV-342 / ET42H
                                       2-F70MDV-350 / ET50H
                                       2-F70MDV-364 / ET64H
Brine Tank:                    ET42H & ET50H
                                       ET64H 

  9” dia. X 56” high
10” dia. X 62” high
12” dia. X 60” high
11” square X 34” high
14” square X 34” high

Salt/Potassium Storage Capacity

11” square X 34” high  = 150 lbs.
11” X 14” X 34” high = 225 lbs.

Approximate Shipping Weight (with no salt)

100-140 lbs.

*Continuous means to a 110 outlet that has continuous voltage not able to be turned off be a light switch.
** Efficiency based at stated factory set salt dosage and maximum service flow rate only. Efficiency determined in 
accordance with NSF/ANSI 44.

Systems conform to NSF/ANSI 44 for the specific performance claims

as verified and substantiated by test data.

  No reduction of specific contaminant claims

Form ETWS 2/07 

 

Page 4 of 20

 

Summary of Contents for ET42H

Page 1: ...Softener Conditioner Systems Models ET42H I ET50H I ET64H P N 2 F70MDV 342 2 F70MDV 350 2 F70MDV 364 Includes Specifications Installation and Service Instructions and Trouble Shooting Guidelines Form...

Page 2: ...ection page 7 Electrical Connection page 7 System Start Up Procedures page 8 Valve Control Programming page 9 Use and Care pages 9 11 Troubleshooting pages 11 12 Power Head Diagram and parts list page...

Page 3: ...actually rinses off much faster with soft conditioned water but you may not feel like the soap is rinsed off because of this slick feeling You will find that if you shower in hard water again it will...

Page 4: ...day time pressure Service Flow Rates 2 F70MDV 342 ET42H 2 F70MDV 350 ET50H 2 F70MDV 364 ET64H 13 7 gpm 15 psi pressure drop 16 0 gpm 15 psi pressure drop 18 6 gpm 15 psi pressure drop Maximum flow ra...

Page 5: ...you must determine where to locate the water softening conditioning system The best location depends on several questions 1 How will you get the water from the water main to the water softener conditi...

Page 6: ...ass position by turning both sides of the valve to the bypass position as shown on top of the bypass valve Note The valve comes with two extra red H clips and one extra gray clip for the brine line co...

Page 7: ...line vertical rise is over 10 feet above the water softener with incoming water supply pressure of 60 psi You can increase or decrease height of run 2 feet per 10 psi variations in either direction i...

Page 8: ...r is draining into the drain properly K Let water run to the drain for about 3 or 4 minutes L Turn off the faucet in the house M Press the Extra Cycle Button again to advance the controller to the nex...

Page 9: ...he Extra Cycle button FACTORY DEFAULT SETTINGS Model Hardness Capacity Salt Calendar Override Grains gallon Kilo grains Pounds Days 2 F70MDV 342 ET42H 18 20 6 15 2 F70MDV 350 ET50H 18 24 7 15 2 F70MDV...

Page 10: ...at a different time of day See step 6 page 9 G Cleaning the Brine Tank Normally it is not necessary to clean the brine tank In time dirt and silt can build up in the brine tank and if you choose you...

Page 11: ...s c Add the sodium hypochlorite solution to the brine well inside the brine tank d Let the softener proceed with the regeneration process Calcium Hypochlorite Calcium hypochlorite 70 available chlorin...

Page 12: ...xcessive water in the brine tank Check salt usage and salt setting Brine draw not functioning Clean or replace injectors Loss of water pressure Iron build up in water softener Inlet of control plugged...

Page 13: ...Form ETWS 2 07 Page 13 of 20...

Page 14: ...Form ETWS 2 07 Page 14 of 20...

Page 15: ...Form ETWS 2 07 Page 15 of 20...

Page 16: ...Bypass Assembly Form ETWS 2 07 Page 16 of 20...

Page 17: ...sembly with safety float 1 Form ETWS 2 07 Page 17 of 20 Item Number No Req d Part Number Description 1 1 40569 7000 Bypass assembly 2 1 40565 10 connector 1 1 4 BSP 3 1 40953 connector 1 1 4 sweat cop...

Page 18: ...h a copy of sales invoice and manufacturer warranty The parts or unit will be repaired or replaced at our option and returned to the customer freight prepaid This warranty does not cover any defects o...

Page 19: ...aser will be entitled to the full benefits of AmeriFlow Water System s warranty KEEP FOR YOUR RECORDS Model __________________________________ Serial __________________________________ Date of Purchas...

Page 20: ...Installed by _________________________________________________ Model __________________________________ Serial __________________________________ Form ETWS 2 07 Page 20 of 20...

Reviews: