MOISTURE ACCUMULATION
At the start/end of each shift, press the MOISTURE DRAIN pushbutton to allow any
water to escape from the pulse accumulator tank. The MOISTURE DRAIN pushbutton
is located on the left front of the AirWall unit.
CHANGING FILTER CARTRIDGES
___________________________________________________________
WARNING
When changing filter cartridges, always wear OSHA-NIOSH approved
respiration equipment, coveralls and gloves. Failure to follow this
instruction may cause serious personal injury.
___________________________________________________________
When it becomes necessary to change filter cartridges, keep in mind that a dirty filter
cartridge weighs between 27 and 30 lbs. The stacked filter cartridge arrangement
weighs between 54 and 60 lbs. Therefore, it is recommended that two (2) people assist
each other in removing the dirty filter cartridges because of the weight dropping down
when the filter cartridge retaining nut is removed from the threaded end of the support
rod. See WARNING.
__________________________________________________________
WARNING
Because of the weight of the dirty filter cartridges, two (2) people
should perform the removal of the dirty cartridges. Failure to follow
this instruction may result in personal injury.
__________________________________________________________
After removing all of the dirty filter cartridges from the AirWall unit, install a new set of
filter cartridges using the procedure outlined in Installation Section, INSTALLING
FILTER CARTRIDGES.
DUST COLLECTION DRAWERS
At the start/end of each shift, check the dust collection drawers located in the bottom of
the air filtration/dust collection unit. Dispose of any waste accumulation according to
federal, state and local environmental regulations. See WARNING
________________________________________________________
WARNING
Always wear OSHA-NIOSH approved respiration equipment when