EnvironmentalLights.com DMX-4-5000-3-10A Manual Download Page 7

Copyright EnvironmentalLights.com 

 

All Rights Reserved 10/1/18 

Safety Precautions

 

Please take the following precautions: 

1.

 

This equipment, like all electrical equipment, should be installed by a qualified person. 

2.

 

Do not expose these LEDs, dimmers or power supplies to intense electro-magnetic fields, 
including lightning. 

3.

 

The controllers and power supplies are not waterproof. Keep them dry. 

4.

 

Always observe proper polarity. 

When installing LED lighting, it is a good idea to follow this “dry-run” procedure: 

1.

 

Be sure you have everything you need before you start. 

2.

 

Lay out your lights and power supply on the floor or table. 

3.

 

There is some resistance in the LED lighting. If you see any color fading or dimming at 
the end of a long run, you may have too many LEDs for your power supply and you 
might need a bigger supply or shorter runs. Use a bus structure as described in 
rgb_manual.pdf. Call if you need assistance with larger projects. 

4.

 

Connect everything and test it to be sure it works and you have it connected properly. It is 
unlikely, but possible, that some part of your system is defective or was damaged during 
shipment. If that is the case, it will be very helpful to you to know that before you do all 
the work involved in installing custom LED lighting systems. You will also know if you 
damage anything during installation, which is really helpful in trouble-shooting because 
manufacturing defects and installation damage typically have very different solutions. 

Once you have tested the system successfully, you are ready to install it. We recommend you 
install LEDs, electronic controls and dimmers in such a way that you have access to them in case 
they fail. All electrical components can fail. 

Summary of Contents for DMX-4-5000-3-10A

Page 1: ...rts in place of the 3 pin DMX ports Both versions have top mounted DIP switches for setting the starting DMX address without needing to apply power Both decoders have built in DMX terminations in addi...

Page 2: ...uency 5 000 Hertz we recommend this decoder for any lighting that may be featured on camera High power DMX LED lighting systems TV and movie sets Specifications Part Number DMX 4 5000 3 10A Dimensions...

Page 3: ...ld be split across several terminals to evenly distribute the current and prevent overloading of the terminal blocks Wiring for Under 30A Make sure the power supply is turned off while wiring the deco...

Page 4: ...10ft or 3m Connect the negative side of the power supply to both DCV terminals Use two runs of wire into each terminal for connections over 10ft or 3m Connect the positive side of the power supply and...

Page 5: ...ly Each decoder can have only one DMX input signal at a time Either RJ45 port can be used as an input or output The DMX IN port should be used for DMX input when connecting with DMX cables The DMX OUT...

Page 6: ...X address is set using switches 1 9 on the 10 slider DIP switch Each switch is marked with its DMX value below Moving any of the switches to the ON position adds the indicated value to the starting DM...

Page 7: ...many LEDs for your power supply and you might need a bigger supply or shorter runs Use a bus structure as described in rgb_manual pdf Call if you need assistance with larger projects 4 Connect everyth...