EWS-HEA
TER-GUARD-3/4
EWS-HEATER-GUARD-3/4 - Exploded View and Parts
Exploded View of 3/4” filter
with Poly-Phosphate Spheres
Unpack and check the HEATER GUARD. Unit comes completely assembled with the following:
5 micron pre-sediment filter with poly-phosphate spheres, housing with cap and mounting bracket, pressure
differential gauge, spanner wrench (other mounting bracket included with all HEATER GUARD-3/4)
NOTE:
Filters contain Poly-Phosphate Spheres which will roll and rattle within the filter.
The sound is normal and nothing is broken.
HEATER GUARD CAN bE REVERSED fOR fLOW DIRECTION fOR ANY INSTALLATION.
HeATer GuArd-3/4:
Flow direction is from left to right. If installation calls for the reverse direction use the other mounting bracket pro-
vided, turn Heater Guard-3/4 around (meter reads from either side) and install using the other mounting bracket
so flow direction can be from right to left.
HeATer GuArd-1.5:
Flow direction is from left to right. If installation calls for the reverse direction remove the 4 screws from bracket
and turn bracket around and reconnect so flow direction will be from right to left. Turn gauge 1/2 turn clockwise
only in order to read.
WARNING
:
Do not loosen the gauge during this procedure.
NOTE:
Whether you use the standard flow direction from left to right or you reverse the installation for the flow direction
from right to left - the inlet side is always designated by a flow direction arrow on the filter cap.
Location: Identify an appropriate mounting location adjacent to the water heater. The HEATER GUARD can be
mounted in both indoor and outdoor locations.
WARNING:
Never allow unit to freeze. Avoid temperatures above 120
o
F or attic locations
If outdoors, unit must be protected from direct sun and heat.
INSTALLATION bOTH SYSTEMS - 7 SIMPLE STEPS
1.
2.