background image

 

ABOUT THE PRODUCT 

 

PRINCIPLE OF OPERATION 

 

The  ENVIROMAC

  Portable  Air  Cleaner  is  a 

media type Air Cleaner operating on a two-stage 
filtration  principle.  After  the  contaminant  is 
picked  up  at  the  hood  of  the  Movex

  Flexible 

Arm  it  is  then  drawn  through  the  arm  and 
through  the  fan  assembly  and  discharged  to  the 
inside  part  of  the  high  efficient  washable  filter. 
The filtered air is discharged out the 2 doors. The 
2  doors  contain  charcoal,  which eliminates most 
gases that might be in the filtered air stream. The 
high  efficient  washable  filter  collects  particulate 
only  and  does  not  filter  gases,  which  is  the  sole 
purpose of the charcoal door filters. 
 

MAJOR COMPONENTS 

 
The ENVIROMAC

 Portable Air Cleaner is a 

self-contained unit comprised of a flexible arm 
(for source capture), fan and motor assembly, 
high efficient washable filter, (2) carbon door 
filters, complete cabinet housing and an 
electrical compartment which also included a 
Contactor overload. 
 
A) HIGH EFFICIENCY HIGH EFFICIENT 
WASHABLE FILTER
 
 
This  filter  is  a  high  efficiency  high  efficient 
washable  filter.  The  suction  will  deteriorate  at 
the  hood  as  the  filter  loads  up  with  particulate. 
Eventually  the  filter  will  have  to  be  cleaned.  To 
commence  cleaning  the  filter,  you  must  remove 
the  doors  closest  to  the  front  of  the  machine 
which  is  where  the  switch  and  nameplate  are 
located.  This  door  is  removed  by  removing  the 
(2) plastic knobs near the bottom of the door and 
then pulling the door out on an angle so the door 
is free from the (2) welded bolts. Then pull down 
on  the  door  to  let  it  slide  down  from  the  top  of 
the door. You then remove the filter by lowering 

the scissor jack with a ratchet. Then slide out the 
cartridge  filter.  You  then  invert  the  filter  upside 
down and utilize the existing gasket on the filter 
to make a seal and take an air hose with about 80 
P.S.I.  and  blow  the  filter  from  the  outside  to 
remove  all  of  the  filter  particulate  that  is  on  the 
inside of the filter. You can now put the cleaned 
filter back into the machine and tighten the filter 
by raising the scissor jack. Make sure the filter is 
resting  on  the  back  of  the  filter  cradle  butted  up 
against the tab locators. Make sure that the top of 
the filter fits inside the top plate that has a 1” lip 
on  it.  Make  sure  the  scissor  jack  is  high  enough 
to  allow  an  airtight  seal  on  the  top  of  the  filter 
gasket. Caution should be taken not to apply too 
much  pressure  to  the  filter  or  you  could  squash 
the filter if too much pressure is applied. Always 
blow  the  outside  of  the  filter  with  the  gasket  of 
the filter either on the floor or a container to give 
you  a  good  seal  so  that  the  dirt  does  not  escape 
under the seal. Never blow from the inside as the 
contaminant  will  blow  all  over  the  surrounding 
area  and  will  also  force  the  very  fine  particulate 
into the media. 
 
B) CHARCOAL FILTERS 
Both doors contain the charcoal filters. They 
should be replaced 1 or twice a year in a normal 
welding environment. 
 
C) ELECTRICAL COMPARTMENT 
 
The unit operates off 120 volts single phase 
utilizing a 20-amp service outlet. The motor 
draws about 13.5 amps under full load 
conditions. There is a Contactor and an overload 
inside this compartment and the overload is set at 
about 20% above the 13.5 amps. This will 
automatically shut off power to the motor in the 
event of an overload. This gives full protection to 
the motor. The unit has a spring activated on/off 
dual switch on the front of the panel. There are 
facilities to put in an optional halogen light in the 
hood of the arm. This requires a 120 Volt to 24 

Reviews: