background image

07-02185A EB280 

Legend Brands  

8. Using the flat blade screwdriver, carefully pry the 
center hub cap loose from the left wheel. Use the 

15

16

 in. 

socket to remove the retaining nut and slide the wheel 
off. See Fig. E, #1. 
9. Remove the two electric box retaining screws (see 
Fig. E, #2.).  
10. Tilt the bottom of the electric box to the right and 
slide outward (Fig. F). It is not necessary to disconnect 
any electrical cables. 
11. Remove drain hose from pump assembly and slide 
pump and tray assembly out of the unit. 
12. Lift pump body out of plastic catch tray.  
13. Wipe or rinse off all surfaces of the plastic catch tray 
with a damp cloth. 
 

CLEANING THE PUMP AND PUMP TRAY 

14. Remove the pump assembly from the pump tray and 
set pump aside. Wipe or rinse out pump tray and wipe 
dry.  
15. Remove pumpout hose from the check valve outlet. 
16. Unscrew check valve. Using needle nose pliers, 
carefully remove bottom of check valve assembly by 
inserting one side of pliers approximately ⅛ in. into hole, 
grasp and pull out carefully. A small ball bearing should 
fall out so be careful not to lose it. Inspect assembly for 
debris in assembly and clean accordingly. Reinstall the 
ball bearing and reinstall the check valve assembly.  

Reassemble in reverse order. The dehumidifier is now 
ready for use.  

Annually 

Have the pump system inspected by the Legend Brands 
Service Department (800-932-3030) or by a qualified 
service center. 

TRANSPORTATION AND STORAGE 

NOTICE:

 Handle the unit carefully. Do not drop, throw, 

or place the unit where it could fall. Rough treatment can 
damage this equipment and may create a hazardous 
condition or void warranty. 

 

 

Do not expose the control panel to moisture, snow 
or rain when transporting in uncovered vehicles such 
as flatbed trucks. 

 

Store and transport securely to avoid any damaging 
impact to internal parts.  

CLEANING COILS AND HEAT 
EXCHANGE BLOCK 

Warning! 

Unplug unit before servicing.

 

To help keep the unit operating efficiently, keep the coils 
and the air-to-air heat exchange block clean. Access 
these components by removing the side and rear covers: 
1. Unplug unit. 
2. Unplug the power cord from the socket at the base of 
the unit. Remove pump hose at quick-connect.  
3. Remove filter. 
4. Remove both side covers A and B (unscrew two bolts 
shown for each panel). 
5. Remove back cover (unscrew the four bolts shown on 
the back and the two bolts on the upper front panel). 
6. Remove the heat exchange block.  
Inspect the heat exchange block carefully. If necessary, 
use compressed air to clear the channels of the block, 
taking care not to damage the block. 

FIG. F: ELECTRIC BOX LOCATION

 

After removing attachment screws (Fig. E), tilt the bottom of the 
electrical box to the right and slide it out. Set aside. It is not necessary 
to disconnect any electrical cables.  

FIG. E: ELECTRIC BOX  
ATTACHMENT SCREWS  

1. After placing a firm support under the base of the unit, remove 
the center hub cap and remove the axle nut. The wheel will now 
slide off. 2. Remove the two screws (shown in the circles above) to 
detach the electric junction box.  

Summary of Contents for EB280

Page 1: ...motor and wiring dry Do not attempt to repair the unit For Authorized Service Centers contact Legend Brands BEFORE YOU BEGIN Warranty If you determine service is required have your equipment model ser...

Page 2: ...Uncoil and straighten the entire drain hose Do not leave any of part of the hose coiled on the unit and do not place the end of the hose higher than 20 ft 6 m above the top of the unit Also check for...

Page 3: ...on or off When the machine is turned on the display normally reads PLEASE WAIT COMP DELAY and performs a numeral countdown for a maximum of 60 seconds to 0 This delay allows time for refrigerant pres...

Page 4: ...nd viewing system information Display setting changes and system information can be accessed by pressing DISPLAY MENU Each press of the key will display the next parameter see list below When you reac...

Page 5: ...30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5 COIL CLEANED 0 HRS Press to cl...

Page 6: ...t in the pocket or the strap provided with your unit MAINTENANCE WARNING ELECTRIC SHOCK HAZARD Unplug the dehumidifier before performing any maintenance Before each use Inspect the electrical cord for...

Page 7: ...ATION AND STORAGE NOTICE Handle the unit carefully Do not drop throw or place the unit where it could fall Rough treatment can damage this equipment and may create a hazardous condition or void warran...

Page 8: ...for instructions To reassemble follow the above steps in reverse Be sure to reinstall heat exchange block in the original orientation When installing the rear cover carefully thread the pump hose thr...

Page 9: ...re to equalize None UNIT ON XXXX HRS INLET XXX F XX First line indicates total operating hours Second line Toggles between inlet temperature and inlet RH every 2 seconds None HUMIDISTAT INLET XXX F XX...

Page 10: ...NVALID MODEL SETTING Incorrect or unsupported DIP switch settings Contact service for correct DIP switch settings ER8 BUTTON STUCK ALL BUTTONS Key is stuck or has been held down too long Contact servi...

Page 11: ...siglas en ingl s No utilice el aparato en agua estancada Mantenga el motor y los cables secos ANTES DE COMENZAR La garant a Si considera que su producto necesita reparaci n tenga a mano el modelo del...

Page 12: ...e aire procesado deshumidificado Puede usarse con un conducto est ndar de 12 30 5 cm r gido o plano FIG A PARTE DELANTERA Armaz n rotomoldeado fuerte resistente a abolladuras y rayones y f cil de mant...

Page 13: ...atro teclas Presione la tecla PRENDIDO APAGADO para prender la unidad C mo usar el panel de control El panel de control tiene una pantalla y una placa sensible al tacto con cuatro teclas PRENDIDO APAG...

Page 14: ...a la cantidad total de horas que ha funcionado la unidad Este valor puede llevarse a cero para hacer un seguimiento de las horas de trabajo vea m s abajo Reinicio de las horas de trabajo La segunda l...

Page 15: ...115 30 S lo para informaci n 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Presione para borrar las horas de limpieza del filtro 5 LIMPIAR BOBINA XXX HRS 5 LIMPIAR BOBINA...

Page 16: ...ores caiga en el rea del colector 3 Pulse la tecla de PURGADO Cuando se complete el ciclo de purgado apague la unidad 4 Desconectar el tubo de drenaje externo escurrir con cuidado enrollarla y fijarlo...

Page 17: ...evante la estructura de la bomba para sacarla de la bandeja pl stica de recolecci n y aparte la bomba LIMPIEZA DE LA BOMBA Y LA BANDEJA DE LA BOMBA 13 Enjuague o limpie con un trapo h medo todas las s...

Page 18: ...del serpent n condensador vertical hasta que est limpio No permita que la boquilla toque las aletas ya que podr a da arlas AVISO El limpiador de serpent n Legend Brands Coil Cleaner pieza n S402 de L...

Page 19: ...ci n Segunda l nea Alterna cada 2 segundos entre la temperatura de entrada y la humedad relativa de entrada Ninguna HIGROSTATO ENTRADA XXX C XX Primera l nea indica que la unidad est en modo de higros...

Page 20: ...st n instalados correctamente en el panel de control Si el error persiste comun quese al centro de servicio ER5 CONEXION SENSOR TABLERO Sensor de temperatura humedad relativa de entrada abierto faltan...

Page 21: ...100 F 1 38 C Construcci n Carcasa rotomoldeada Seguridad Certificaci n de ETL conforme a las normas CSA 22 2 n 92 Las especificaciones est n sujetas a cambios sin previo aviso Algunos valores pueden...

Page 22: ...teur Ne jamais sectionner la troisi me fiche Ne pas utiliser de rallonge L appareil doit fonctionner sur un circuit de 115V 60 Hz prot g par un disjoncteur de fuite la terre Ne pas mettre l appareil e...

Page 23: ...ge optimal contactez Legend Brands au 800 932 3030 IDENTIFICATION DES PI CES FIG A AVANT Panneau de commande R ceptacle moul pour rangement du cordon Entr e d air humide 2 c t s Sortie d air trait d s...

Page 24: ...nsion Mode d emploi du panneau de commande Le panneau de commande comprend un cran et un clavier tactile avec quatre touches MARCHE ARR T Appuyez sur la touche Marche Arr t pour mettre l appareil en m...

Page 25: ...FFICHAGE Appuyez pour s lectionner l article suivant du menu L article du menu apparaitra sur l affichage S LECTION DU MENU TOUCHE VERS LE HAUT Appuyez pour faire d filer ou s lectionner les valeurs a...

Page 26: ...ormation seulement 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Appuyer sur pour effacer les heures du filtre 5 LIMPIAR BOBINA XXX HRS 5 LIMPIAR BOBINA 0 HRS Appuyer sur p...

Page 27: ...e l eau restant sur les surfaces int rieures s coule dans le puisard 3 Appuyez sur la touche PURGE Lorsque le cycle de purge est termin teignez l unit 4 D brancher le tuyau de vidange externe goutter...

Page 28: ...de fa on appropri e Remettez en place le roulement puis le clapet de non retour R assemblez les articles en suivant les tapes en sens inverse Le d shumidificateur est maintenant pr t l emploi Tous les...

Page 29: ...nt tre utilis sur le serpentin froid vaporateur horizontal Suivez les instructions fournies sur l tiquette du produit Veillez ne pas vaporiser ou taler le nettoyant pour serpentins sur des composants...

Page 30: ...fonctionnement Seconde ligne Alterne entre la temp rature d entr e et RH d entr e toutes les 2 secondes Aucune HIGROSTATO ENTRADA XXX C XX Premi re ligne indique que l unit est en mode hygrostat Secon...

Page 31: ...s capteurs de temp rature sont install s correctement sur le panneau de commande Si l erreur persiste contacter le fournisseur de services ER5 CONEXION SENSOR TABLERO Le capteur de la temp rature Rh d...

Page 32: ...38 C Construction Enveloppe rotomoul e S curit Certifi ETL pour CSA 22 2 no 92 La fiche technique peut tre modifi e sans avis pr alable Certaines valeurs peuvent tre approximatives Vitesse variable au...