Figure 38: Removal of Stove Top
c
onveRting
t
oP
v
enteD
into
R
eaR
v
enteD
:
This unit has been shipped as a 30,000 Btu/hr top-vented freestanding unit. This unit can be converted
to a rear vented unit with a 36” (915 mm) snorkel for some installation applications.To convert this unit
to a rear vented model you must remove the flue pipe adapter and turn to the rear vent position. See
sections
I
nItIal
I
nstallatIon
- I
nstallatIon
oF
r
ear
v
ented
a
PPlIance
.
1. Carefully remove the stovetop and place on a soft surface as not to damage the painted finish (see
Figure 38).
2. Remove the four (4) ¼” screws that hold the flue collar elbow to the unit body (see Figure 39).
3. Carefully remove the elbow being sure not to damage the gasket that is glued to the flue collar elbow,
it seals the flue to the firebox.
4. Turn the elbow to the rear vent position and re-fasten with the screws removed in step 2 (see Figure
40).
5. Install the half-moon shaped trivet, supplied with the stove, onto the rear of the stovetop using the
two screws provided and re-install the stovetop.