Enviro S30I Owner'S Manual Download Page 45

Rating Label

Certified for use in Canada & USA /

Certifié pour installation au Canada et aux 

Etats-Unis.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

LISTED GAS FIREPLACE HEATER / 

LISTE DES 

APP

AREILS 

AU GAZ VENTILÉS

 

Serial No. / No. De Serié:

DATE OF MANUFACTURE / 

DATE DE FABRICATION:

J       F       M       A       M       J       J       A       S       O       N       D                 2015      2016       

2017      2018       2019

C-14558

MANUFACTURED BY / 

FABRIQUE PAR

: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD, SAANICHTON, BC CANADA

MADE IN CANADA / 

FABRIQUE AU CANADA

Model 

Modèle:

S30 Nova Log Burner

S30I IPI Log Burner

4001609

Fuel 

Carburant:

NA

T

(Gaz naturel)

LPG (Propane)

INPUT

 (E

NT

À) at 0-4500 feet/pied  (0-1372 m):

NA

T (Gaz naturel)

LPG (Propane)

MAX:  20,000 Btu/hr (5.86 kWh) MIN:   13,600 Btu/hr (3.98 kWh)

MAX:  18,500 Btu/hr (5.42 kWh) MIN:   14,500 Btu/hr (4.25 kWh)

MANIFOLD PRESSURE  (P

RE

SS

IO

DE

CO

ND

UI

TS

):

ORIFICE SIZE (

GROSSEUR DE L'ORIFICE

):

# 46 

1.2 mm

GAS SUPPL

Y PRESSURE 

(P

RE

SS

IO

D'

AP

PR

O

VI

SI

O

NN

EM

EN

DU

 G

AZ

):

MAX: 3.5 inch W

.C.  (0.87 kPa) 

MIN:  1.5  inch W

.C. (0.37 kPa)

MAX: 10 inch W

.C.  (2.49 kPa) 

MIN:  6.4  inch W

.C. (1.59 kPa)

MAX: 7 inch W

.C.  (1.74 kPa) 

MIN:  4.5 inch W

.C. (1.12 kPa)

MAX: 1

1 inch W

.C.  (2.74 kPa) 

MIN:  10.4 inch W

.C. (2.59 kPa)

DV

CAUTION/A

TTENTION

Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids h

aving flammable vapours away / Chaud pendant 

le fonctionnement. Ne touchez pas. Des brûlures gr

aves peuvent en résulter

. Gardez les enfants, les vêtements, meubles, essence et autres liquides ayant des vapeurs inflammables loin.

CONFORMS 

TO / Conforme :  

ANSI Z21.88-2014, CERITIFIED 

TO / 

Agréé : CSA

 

2.33-2014

 VENTED GAS FIREPLACE HEA

TERS /  

APP

AREIL

 DE CHAUFF

AGE À 

ÉV

ACUA

TION DIRECTE, CAN/CGA

 2.17-M91 (R2014) GAS FIRED 

APPLIANCES FOR 

HIGH 

AL

TITUDES / 

APP

AREIL

 AU GAZ POUR HAUTES 

AL

TITUDES. 

This appliance 

equipped o

nly for altitudes 0-2000 feet (0-610 m). In Canada 0-4500 feet (1370 m) / Cet 

appareil pe

ut être utilisé à des altitudes comprises entre 0 et 610 mètres (0 et 2000 pieds) 

seulement. En Canada 0 et 1370 mètres (0-4500 pieds). For use only with barriers Part  Numbers 50-3070. Follow installation instructions / Utiliser uniquement avec l’écran no  50-3070. Suivre les instructions d’installation. 

CAUTION/A

TTENTION

Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel should be done by a licensed of qu

alified service person / 

Ne pas faire 

fonctionner l'appareil avec un verre enlevée, fissurée ou 

cassée. Remplacement du panneau doit être ef

fectuée par une personne de service certifié ou qualifié.

CLEARANCES TO COMBUSTIBLES /  CLAIRANCE DES COMBUSTIBLES:

All Models Minimum Alcove / tous les  modèles alcôve minimum:

 

From Sides / partir de côtés: 10.75” (273mm) From Back / de l'arrière: 4” (101.6mm) From Top / de haut: 12.0” (304.8mm) Floor / étage: N/A

VENT PIPE CLEARANCES

: See manufacturer’s listing, label and installation instructions. May be installed in a bedroom or 

bedsitting room (IN CANADA a listed wall thermostat). The total vent length must be between 7in (17.7cm) and 44ft (13.4m). 

This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation 

instructions. If any of the venting is disassembled after installation, it must be properly resealed according to the instructi

ons 

in the owners manual. This appliance must be installed in accordance with local codes, if any; if none, follow the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. This vented gas 

fireplace heater is not for use with air filters. FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY. 

This appliance is only for use with the type of fuel indicated on this rating label. See owner's manual for details. This 

appliance is not convertible for use with other gases, unless a certified kit is used. Keep burner and control compartment 

clean. See installation and operating instructions accompanying appliance. 

.

 WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically appro

ved with this appliance may result in property damage or personal injury. WARNING: Do not operate the 

appliance until all sections have been assembled and installed 

in accordance with the manufacturers instructions. This model c

an be vented with approved 4” x 6 ⅝“ galvanized or stainless st

eel solid vent. 

CL

AIR

AN

CE

 D

ES

 T

UY

AU

X D

E V

EN

TIL

AT

IO

N: C

on

su

lte

z l

es

 lis

te

s, l

es

 é

tiq

ue

tte

s e

t l

es

 in

str

uc

tio

ns

 

d'installation du manufacturier

. Ces appareils peuvent être installés dans une chambre à coucher (au CANADA

 avec thermostat mural). La longueur totale du conduit doit être comprise entre 7 pouces (17.7cm) et 44 pieds (13.4m). Pour une

 installation dans un âtre ventilé et composé de matériaux non 

combustibles.  Si aucun code n'existes, utilisez les codes ci-inclus : CAN/CGA

 B149 au Canada ou 

ANSI Z223.1 / NFP

A 54 aux États-Unis. Cet appareil au gaz ne doit pas être utilisé avec des filtres à air

. POUR UTILISA

TION UNIQUEMENT

 A

VEC LES POR

TES EN VERRE CER

TIFIÉES 

AVEC L

’APP

AREIL. 

 Ve

nte

d G

as

 Fir

ep

lac

e H

ea

ter

 - N

ot f

or

 U

se

 w

ith

 So

lid

 Fu

el

Foyer au gaz à évacuation. Ne pas utiliser avec du combustible solide.

W

ARNING/A

VERTISSEMENT

: Fire or explosion hazard. Can cause property damage, severe injury

or death. 

This is a fast-acting thermocouple. Replace it only w

ith another fast-acting thermocouple specified 

by the manufacturer

. Refer to the manual for the part number 

/ Risque d’incendie ou d’explosion. Peut 

entraîner des dommages matériels, des blessures graves ou 

la mort. Ceci est un thermocouple rapide. Peut 

être remplacé uniquement par un autre thermocouple rapide s

pécifié par le fabricant de l’appareil. V

euillez 

consulter à la notice pour le numéro de pièce

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance / S’assurer que l

e brûleur et le compartiment des commandes sont propres. V

oir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

VITRE CHA

UDE – 

RISQUE

DE BRÛL

URE

S.

NE T

OUCHE

Z P

AS 

UN

E

VITRE N

ON REFR

OIDIE.

NE LAISSE

Z J

AMAIS 

UN

ENF

AN

T T

OUCHER LA VITRE.



de

 brûlur

e en c

as de c

on

tact acciden

te

l a

ve

c la vitr

e

et des per

sonne

s à risques.

HO

T GLASS 

WILL 

CA

USE BURN

S

DO NO

T T

OUCH 

GLASS 

UN

TIL C

OOLED

NEVER

 ALL

OW CHILDREN

TO T

OUCH GLASS. 

A barrie

r designe

d t

o r

educe

 the

 risk

 of burns fr

om the

hot vie

wing glass is pr

ovided with this appliance and shall 

individuals.

Les appareils de chauf

fage à évacuation direct ne doivent pas être utilisés avec des carburants solides. Utilisez seulement des 

portes vitrées approuvées pour cet appareil. 

AVER

TISSEMENT

: Si vous installez cet appareil selon les instructions du fabricant 

ou de l'échec d'utiliser seulement les pièces spécifiquement approuvé avec cet appareil peut entraîner des dommages matériels 

ou corporels.Cet appareil doit être utilisé seulement avec le type de carburant mentionné et requis sur l'étiquette de classifi

cation 

de cet appareil. Consultez le guide du propriétaire pour plus de détails. Cet appareil ne peut être converti pour utilisation a

vec 

d'autres gaz que celui mentionné sur l'étiquette de classification, sauf si une trousse de conversion certifiée est utilisée. 

AVER

TISSEMENT

: Ne faites pas fonctionner l'appareil tant que toutes les pièces et les sections ne soient pas assemblées et/ou 

installées en concordance avec les instructions du manufacturie

r. Ce modèle peut être évacué avec approuvé 4"x 6 ⅝" partie 

galvanisé ou en acier inoxydable solide évent. 

ELECTRICAL

 REQUIREMENTS / BESOINS ÉLECTRIQUES:

  

115 V 

AC, 60 Hz, 0.9 

Amp (fan type vented circulator

Sherwood Industries Ltd Part  #50-2493 / V

entilateur de type cage d'écureuil, Les Industries Sherwood Ltée. Pièce #50-2493

S

AMPLE

45

Summary of Contents for S30I

Page 1: ...property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 4001609...

Page 2: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifi...

Page 3: ...be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54...

Page 4: ...emoval 16 Fuel Conversion 16 Initial Installation 19 Introduction 19 Preparation for Installation 19 Clearance to Combustibles 19 Rear Vent Conversion 20 Direct Vent 22 Venting Clearances 22 Approved...

Page 5: ...ATERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO S30I Fireplace Has been certified for use with ei...

Page 6: ...on The rating label is located on the backside of the valve access door Figure 5 and the lighting instructions are attached to a ball chain underneath the control panel 35 7 8 91 1 cm 22 1 2 57 2 cm 2...

Page 7: ...nce and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the owner s manual...

Page 8: ...attained turn off the gas and contact the dealer Warning Incorrect shutter adjustment may lead to improper combustion which is a safety hazard Contact the dealer if there is any concern about the vent...

Page 9: ...smitter is powered by three 3 AAA type batteries A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 4 5 Figur...

Page 10: ...via radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is us...

Page 11: ...display see Figure 7 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the IFC will confirm reception o...

Page 12: ...re and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key Figure 4 unt...

Page 13: ...the First Time Figure 14 Remote Control Locked Figure 15 Low Battery Indicator WARNING Fire Hazard Can cause severe injury or death The IFC causes ignition of the appliance The appliance can turn on...

Page 14: ...r installation Use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass and painted surfaces Depending on the amount of use the glass should require cleaning no more than two...

Page 15: ...hetoplatchesareunhooked lean the door forward and then lift it up out of the alignment slots at the bottom corners of the firebox shown in Figure 18 To replace the glass door simply reverse the above...

Page 16: ...G 46 DMS or LP 1 2 mm 1 Servo Regulator with diaphragm 1 Installation instruction sheet 1 Conversion label Carefully inspect all parts supplied with this conversion kit If any parts have been damaged...

Page 17: ...adjustment screw figure 54 page 41 clockwise to decrease or counterclockwise to increase until the correct flame is achieved Conversion Kit Installation 1 Turn the unit off by pressing the ON OFF Key...

Page 18: ...r to your American Gas Association guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m...

Page 19: ...ding e g cutting a wall or ceiling joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room tha...

Page 20: ...ble Venting Configurations before final installation Step 2 Next remove the vent collar base plate cover plate and exhaust spigot 28 screws total as shown in Figure 24 Vent Collar Base Plate Exhaust S...

Page 21: ...f holes when setup as a rear vent Figure 25 Vent Conversion Step 3 Use lower set of holes Initial Installation QUALIFIED INSTALLERS ONLY Cast Vent Cover Step 4 Re install the cast top by aligning the...

Page 22: ...ration of the venting pipes depends on the locations of walls ceilings and studs However the pipes cannot be of arbitrary length and arrangement Because the length of the vertical and horizontal secti...

Page 23: ...ll strap support band 970 4DT HKA SV0SHK 4DHTK1 Horizontal termination kit SD Basic Kit SEL Kit A SC Standard Kit 911 11 to 14 pipe adjustable 4DT AJ 4D12A 4 to 10 pipe adjustable SV4LA12 1 to 12 pipe...

Page 24: ...d through wall thimble The S30I can be installed in rear vent applications with no vertical rise within the parameters as shown in Figures 28 and 29 Refer to the Initial Installation Venting Terminati...

Page 25: ...the cabinet side panels see Figure 30 SSecure the S30 to the floor using the two holes one per side in the pedestal and hearth pad if used see Figure 30 Insure the unit is electrically grounded to the...

Page 26: ...may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distan...

Page 27: ...better than a longer one When top vented the total length of horizontal vent pipe can not exceed 14 feet 4 27m and the total vent length can not exceed 44ft 13 4m Any combination of rise and run can...

Page 28: ...ve the log set air diffuser and creamic brick panels see Secondary Installation Optional Porcelain Panels Installation and Removal then remove the set screws as shown on each side of the firebox Next...

Page 29: ...he air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal pipe...

Page 30: ...the vent cap assembly to the outer wall of the vent pipe Bend any remaining portion of the strap back towards the vent cap Security Secure Vent uses a twist lock cap Step 5 Position the horizontal ve...

Page 31: ...hing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you h...

Page 32: ...should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 27 4 Any occupied areas above the first floor including plumber s tape connected to wall strap Wall st...

Page 33: ...the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always che...

Page 34: ...tions or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong grounding plug for your protectio...

Page 35: ...ocator pins Figure 42 Back Log and Ember Bed Installation Figure 43 Coal Nuggets Installation Step 1 Place the back log on the top legde of the air duffuser with back up against the rear brick panel I...

Page 36: ...tly curved twig on the far right side by locating the bottom of it on the far right log grate upright The top will rest on the smooth section of the middle ember bed twig Step 4 Next install the secon...

Page 37: ...te upright by locating the notch on the bottom side with the log grate cross bar The top of the twig will rest on top of the far right curved twig The last remaining straight twig gets intalled by loc...

Page 38: ...ed in the previous section 10 Re Install the glass door Secondary Installation Optional Porcelain Panels 50 2939 Installation and Removal Turn off the gas control knob and allow the unit to cool Pleas...

Page 39: ...the steps below Step 1 Turn off the S30I and allow it to fully cool down Step 2 Remove the cast door as instructed in the Maintenance and Service Cast Door Removal section Step 3 Remove the seven reta...

Page 40: ...ll blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Igni...

Page 41: ...k the correct gas type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC bo...

Page 42: ...mpingement on thermopile Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases...

Page 43: ...n Liners Set 4 pieces 50 2939 17 Ceramic Brick Liner Set 3 pieces 50 2938 Ceramic Ledgstone Liner Set 3 pieces 50 2972 18 Proflame 2 Integrated Fireplace Control IFC 50 3010 Proflame 2 IFC Wire Harnes...

Page 44: ...Parts Diagram 2 25 26 10 4 3 23 9 6 7 18 5 12 13 22 27 24 14 15 17 16 21 1 8 11 28 20 19 44...

Page 45: ...other gases unless a certified kit is used Keep burner and control compartment clean See installation and operating instructions accompanying appliance WARNING Failure to install this appliance per th...

Page 46: ...Notes 46...

Page 47: ...including serial number This warranty does not cover any discoloration of the safety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warra...

Page 48: ..._______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyy...

Reviews: