Enviro S30I Owner'S Manual Download Page 1

OWNER’S MANUAL

50-3084

WARNING: 

 If the information in this manual is not followed exactly, a 

fire or explosion may result causing property damage, personal injury 

or loss of life. Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

  Version Française: www.enviro.com/fr.html

4001609

W

AR

RA

NT

Y R

EG

IST

RA

TIO

N

enviro.com/warranty

S30I

F R E E S T A N D I N G   G A S   F I R E P L A C E

Summary of Contents for S30I

Page 1: ...property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 4001609...

Page 2: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifi...

Page 3: ...be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54...

Page 4: ...emoval 16 Fuel Conversion 16 Initial Installation 19 Introduction 19 Preparation for Installation 19 Clearance to Combustibles 19 Rear Vent Conversion 20 Direct Vent 22 Venting Clearances 22 Approved...

Page 5: ...ATERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO S30I Fireplace Has been certified for use with ei...

Page 6: ...on The rating label is located on the backside of the valve access door Figure 5 and the lighting instructions are attached to a ball chain underneath the control panel 35 7 8 91 1 cm 22 1 2 57 2 cm 2...

Page 7: ...nce and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the owner s manual...

Page 8: ...attained turn off the gas and contact the dealer Warning Incorrect shutter adjustment may lead to improper combustion which is a safety hazard Contact the dealer if there is any concern about the vent...

Page 9: ...smitter is powered by three 3 AAA type batteries A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 4 5 Figur...

Page 10: ...via radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is us...

Page 11: ...display see Figure 7 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the IFC will confirm reception o...

Page 12: ...re and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key Figure 4 unt...

Page 13: ...the First Time Figure 14 Remote Control Locked Figure 15 Low Battery Indicator WARNING Fire Hazard Can cause severe injury or death The IFC causes ignition of the appliance The appliance can turn on...

Page 14: ...r installation Use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass and painted surfaces Depending on the amount of use the glass should require cleaning no more than two...

Page 15: ...hetoplatchesareunhooked lean the door forward and then lift it up out of the alignment slots at the bottom corners of the firebox shown in Figure 18 To replace the glass door simply reverse the above...

Page 16: ...G 46 DMS or LP 1 2 mm 1 Servo Regulator with diaphragm 1 Installation instruction sheet 1 Conversion label Carefully inspect all parts supplied with this conversion kit If any parts have been damaged...

Page 17: ...adjustment screw figure 54 page 41 clockwise to decrease or counterclockwise to increase until the correct flame is achieved Conversion Kit Installation 1 Turn the unit off by pressing the ON OFF Key...

Page 18: ...r to your American Gas Association guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m...

Page 19: ...ding e g cutting a wall or ceiling joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room tha...

Page 20: ...ble Venting Configurations before final installation Step 2 Next remove the vent collar base plate cover plate and exhaust spigot 28 screws total as shown in Figure 24 Vent Collar Base Plate Exhaust S...

Page 21: ...f holes when setup as a rear vent Figure 25 Vent Conversion Step 3 Use lower set of holes Initial Installation QUALIFIED INSTALLERS ONLY Cast Vent Cover Step 4 Re install the cast top by aligning the...

Page 22: ...ration of the venting pipes depends on the locations of walls ceilings and studs However the pipes cannot be of arbitrary length and arrangement Because the length of the vertical and horizontal secti...

Page 23: ...ll strap support band 970 4DT HKA SV0SHK 4DHTK1 Horizontal termination kit SD Basic Kit SEL Kit A SC Standard Kit 911 11 to 14 pipe adjustable 4DT AJ 4D12A 4 to 10 pipe adjustable SV4LA12 1 to 12 pipe...

Page 24: ...d through wall thimble The S30I can be installed in rear vent applications with no vertical rise within the parameters as shown in Figures 28 and 29 Refer to the Initial Installation Venting Terminati...

Page 25: ...the cabinet side panels see Figure 30 SSecure the S30 to the floor using the two holes one per side in the pedestal and hearth pad if used see Figure 30 Insure the unit is electrically grounded to the...

Page 26: ...may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distan...

Page 27: ...better than a longer one When top vented the total length of horizontal vent pipe can not exceed 14 feet 4 27m and the total vent length can not exceed 44ft 13 4m Any combination of rise and run can...

Page 28: ...ve the log set air diffuser and creamic brick panels see Secondary Installation Optional Porcelain Panels Installation and Removal then remove the set screws as shown on each side of the firebox Next...

Page 29: ...he air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal pipe...

Page 30: ...the vent cap assembly to the outer wall of the vent pipe Bend any remaining portion of the strap back towards the vent cap Security Secure Vent uses a twist lock cap Step 5 Position the horizontal ve...

Page 31: ...hing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you h...

Page 32: ...should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 27 4 Any occupied areas above the first floor including plumber s tape connected to wall strap Wall st...

Page 33: ...the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always che...

Page 34: ...tions or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong grounding plug for your protectio...

Page 35: ...ocator pins Figure 42 Back Log and Ember Bed Installation Figure 43 Coal Nuggets Installation Step 1 Place the back log on the top legde of the air duffuser with back up against the rear brick panel I...

Page 36: ...tly curved twig on the far right side by locating the bottom of it on the far right log grate upright The top will rest on the smooth section of the middle ember bed twig Step 4 Next install the secon...

Page 37: ...te upright by locating the notch on the bottom side with the log grate cross bar The top of the twig will rest on top of the far right curved twig The last remaining straight twig gets intalled by loc...

Page 38: ...ed in the previous section 10 Re Install the glass door Secondary Installation Optional Porcelain Panels 50 2939 Installation and Removal Turn off the gas control knob and allow the unit to cool Pleas...

Page 39: ...the steps below Step 1 Turn off the S30I and allow it to fully cool down Step 2 Remove the cast door as instructed in the Maintenance and Service Cast Door Removal section Step 3 Remove the seven reta...

Page 40: ...ll blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Igni...

Page 41: ...k the correct gas type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC bo...

Page 42: ...mpingement on thermopile Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases...

Page 43: ...n Liners Set 4 pieces 50 2939 17 Ceramic Brick Liner Set 3 pieces 50 2938 Ceramic Ledgstone Liner Set 3 pieces 50 2972 18 Proflame 2 Integrated Fireplace Control IFC 50 3010 Proflame 2 IFC Wire Harnes...

Page 44: ...Parts Diagram 2 25 26 10 4 3 23 9 6 7 18 5 12 13 22 27 24 14 15 17 16 21 1 8 11 28 20 19 44...

Page 45: ...other gases unless a certified kit is used Keep burner and control compartment clean See installation and operating instructions accompanying appliance WARNING Failure to install this appliance per th...

Page 46: ...Notes 46...

Page 47: ...including serial number This warranty does not cover any discoloration of the safety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warra...

Page 48: ..._______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyy...