Initial Installation
QUALIFIED INSTALLERS ONLY
i
ntRoDuction
:
This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement,
hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems.
There are several installation safety guidelines that must be adhered to. Please carefully read the safety
precautions at the front of this manual.
NOTE: The Q2G models can ONLY be run as a top vent; the rear vent is only available for the Q2L models.
CAUTION:
Clearances must be sufficient to allow access for maintenance and service.
p
Lacement
anD
f
Raming
:
Table 2. Framing Dimensions.
Minimum Construction Framing
Depth
15
7/8
”
403mm
Width
34
9/16
”
878mm
Header
40”
1016mm
Height - Top Vent
*54”
1372mm
Gas Inlet (Distance
From Front)
6”
152mm
Gas Inlet (Height) 1
9/16
” 40mm
Figure 23. Dimensions for Framing the Firebox
37
7
/
8
"
(962mm)
36¼"
(921mm)
3
5
/
8
"
(93mm)
13
1
/
4
"
(337mm)
5
5
/
8
"
(143mm)
Gas
Inlet
Adjac
ent w
all
1" min
(25mm)
14”
(356mm)
Minimum Framing Dimensions
Depth
15
7/8
”
403mm
Width
34
9/16
”
878mm
Header Height
40”
1016mm
Chase Height
(Rear Vent)
43
1/2
”
1105mm
Chase Height
(Top Vent)
*54”
1372mm
Gas Inlet (Front)
6”
152mm
Gas Inlet (Height)
1
1/4
”
33mm
The location for the fireplace can be along a wall,
raised, at floor level, or in a corner. There are specific
framing measurements for each situation. The basic
opening should have the dimensions shown in Figure
23. The fireplace must have a strong and level surface
to be placed on. The surface should be made of wood
or a non-combustible material, not carpet.
The gas line,
3/8” JIC fitting
, should be brought to
the right side of the fireplace. The location should be
chosen so the fireplace will be at least
36 inches (914
*Minimum dimension with only an elbow off the top.
Any vertical rise added increase the chase height
respectively.
40”
(1016mm)
15
7/8
”
(403mm)
34
9/16
”
(878mm)
6”
(152mm)
1
9/16
”
(40mm)
NOTE: When framing the unit, care must be taken
to consider the final floor thickness, the bottom of
the fireplace must sit flush with the finished floor.
37.25"
[946.15 mm]
MIN
mm) from drapes, doors and other combustibles. The framed opening should also be a minimum of 4
5/8” (117 mm) from the nearest perpendicular wall (sidewall to the edge of the opening).