Safety Warnings & Recommendations.........................................................................................2
Installation............................................................................................................................3
 

Heat Distribution Kit.........................................................................................................3

 

Ducting Specifi cations.......................................................................................................8

 

Wiring  ..............................................................................................................................9

 

Wiring  Diagram...............................................................................................................10

Parts  List....................................................................................................................................11

      SAFETY WARNINGS & RECOMMENDATIONS                                           

 

Please read this entire Technical Manual before installing or operating your Enviro Pellet Stove with 

Heat Distribution Kit. Failure to follow these instructions may result in property damage, bodily injury or even 
death.  Any unauthorized modifi cation of the stove or Heat Distribution Kit is prohibited. All national and local 
regulations must be followed when operating this pellet stove with Heat Distribution Kit option.

WARNING:

 DO NOT INSTALL IN SLEEPING ROOM.

CAUTION:

  THE  STRUCTURAL  INTEGRITY  OF  THE  MANUFACTURED  HOME  FLOOR,  WALL,  AND 

CEILING/ROOF MUST BE MAINTAINED. 

Installation: 

Ducting must have 1” clearance to any combustible material when going through a wall or fl oor. 

Do not use plastic registers, metal registers must be used for Heat Distribution Kit installation. 

Do not cover or 

block outlet registers. 

Do  not  have  combustible  materials  touching  outlet  registers.  Give  wall  registers  at  least  6  inches  of  clearance  to 
furniture, clothing ect. 

Do place anything directly above or in contact with fl oor registers.

 

The installer must use supplied 1/4 inch insulation 

between register adapters and combustible building materials. Ducting register adapters can not be installed with zero 
clearance.

Unit can not be ducted into previously existing heating appliance ducts. Ducts for HDK must be installed as per manual.

Duct runs should be 20ft or less, output will greatly decline after this length.

Operation:

 Metal registers attached to Heat Distribution Kit ducting must be open during operation. 

Do not touch any part of stove or Heat Distribution Kit while stove is running.  

Unit is hot during operation. Keep 

children, clothing and furniture away. Contact may cause skin burns.

  After unit is off give at least one hour before 

touching stove, registers, or refueling. 

To access Heat Exchanger cleaning rods remove front grills. Wait until unit is cool to access.

Unit

 MUST

 be set to Hi/Lo or Auto/Off mode for Heat Distribution Kit to function properly. The high limit switch will 

turn off unit in manual mode if wired correctly.

Summary of Contents for Maxx-1

Page 1: ...IRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT YOUR LOCAL BUILDING O...

Page 2: ...not have combustible materials touching outlet registers Give wall registers at least 6 inches of clearance to furniture clothing ect Do place anything directly above or in contact with oor registers...

Page 3: ...sides by opening rebox and ash pan door handles and loosen three 8 T 20 mounting screws on each side of stove Loosen Loosen Loosen Loosen Figure 1 Adjustment knob and lock collar removal Figure 2 Cab...

Page 4: ...Front Grill assembly four T 20 screws Figure 3 Cabinet sides removal Figure 4 Original front gill removal 5 Remove Front Top assembly four screws Figure 5 Front Top assembly removal 6 Remove four scre...

Page 5: ...et removal Figure 8 Front HDK assembly install 9 Install Back HDK assembly rst attach back plate using original hinge screws and existing hinge mount holes 10 Attach the hopper extension side anges wh...

Page 6: ...ginal Front Top assembly with two 8 sheet metal screws Use front hole on Front top assembly side anges These will match up to holes on the sides of the Front HDK assembly Figure 11 Install of duct shi...

Page 7: ...justment knob The opposite of steps 1 2 17 Attach 4 diameter 20 24 gauge galvanized or aluminum ducting to outlets on HDK Ducts should slide through holes in the back plate and on to outlet tubes 18 I...

Page 8: ...ll or oor Duct runs should be less than 20ft for best results Wall 1 4 Insulation Wall and oor registers must be installed with supplied 1 4 insulation between ducting to register adapter and the comb...

Page 9: ...ard The circuit board will need to be detached from the frame a small at head screw driver will be required to connect wires see Figure 21 d There will be a purple wire coming form the circuit board t...

Page 10: ...10 Wiring Diagram...

Page 11: ...ription Replacement No 1 HDK Back Assembly 2 HDK Front Assembly 3 Lid Gasket 4 Cabinet Side Extention 5 Duct Shield 6 Slider Grill 7 Grill 8 Sensor Assembly 9 High Limit Sensor 220F EC 002 10 Fan Sens...

Page 12: ...12 MANUFACTURED BY SHERWOOD INDUSTRIES LTD 6782 OLDFIELD RD SAANICHTON BC CANADA V8M 2A3 www enviro com Oct 7 2013 C 14262...