Installation
S
lider
/d
amper
S
et
-u
p
:
This is used to regulate the airflow through the pellet stove.
Convection
Fan
Slider
Damper
Slider Damper
Set Screw with
5
/
16
" Hex Head
Removable Plate
& Exhaust Sensor
location
Combustion
Blower
Note: The side panel,
& back grill are
removed for clarity.
Figure 19: Slider/Damper Plate & Rod in Unit.
Figure 20: Efficient Flame.
18
This unit is designed to operate within a negative pressure range of
0.15-0.17 inches of water column (37-42
Pa).
This can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5
setting after one hour of burn time. This adjustment is necessary for varying venting configurations. The reading
can be taken from the ⅛” hole located on the right side of the Ash Box.
The Combustion Trim, Feed Trim and Fuel Type Functions can be used to compensate for varying fuel qualities.
Refer to the Owners Manual for circuit board operation.
If, after long periods of burning, the fire builds up or there is a build up of clinkers, this would be a sign that the
fuel quality is poor - this requires more air.
The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of the fire.
• A tall, lazy flame with dark orange tips requires more air.
• A short, brisk flame, like a blowtorch, has too much air .
• If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black
tips then the air is set for proper operation, refer to Figure 20.
SPECIAL NOTES:
Fuel quality is a major factor in how the stove will operate. If the fuel has a high moisture content or ash content the
fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).