32
Initial Installation
QUALIFIED INSTALLERS ONLY
Flex Vent
Flex Cap
Flex Thimble
Figure 43. Flex Vent Install
Step 1.
Install supplied thimble into exterior
wall framing and seal with an
approved sealant.
Step 2.
Termination already comes secured
to the the flex venting, do not
detach. Insert spacer springs around
inner pipe and space out evenly.
Feed venting through thimble from
the exterior.
Step 3.
Secure termination cap to exterior
wall using supplied screws. Use
an approved sealant around the
perimeter of the cap.
Step 4.
Apply a liberal bead of sealant
around the perimeter of the fireplace
vent collar then attach flex venting.
Secure the inner exhaust pipe first,
then the outer, using self-taping
screws.
F
Lex
V
entinG
:
This fireplace is only certified to work with certain BDM Pro-Form and Duravent flexible direct venting
systems. Not all rigid venting configurations are allowable when using flex venting. Only horizonally
terminated applications will work with a vertical rise between 18” (457mm) and 78” (1981mm) measured
from the top of the unit.
If your vertical rise is between 18” (457mm) and 30” (762mm) use 50-3374 5ft kit.
If your vertical rise is between 30” (762mm) and 78” (1981mm) use 50-3404 10ft kit.
Important Information:
-Do not bend over 90 degrees.
-All horizontal runs should have a minimum 1/4” (6mm) rise per foot for optimal performace.
-Do not allow the inner flex pipe to contact the outer pipe, keep it pulled tight and use spacer springs.
-Spacers are required at the start, middle, and end of each elbow to ensure the gap is maintained.
-Do not add any extensions to the preset kits, if more length is required, use rigid pipe.
Approved Flex Vent Kits:
Duravent 5ft kit
Duravent 10ft kit
BDM Pro-Form 5ft kit
BDM Pro-Form 10ft kit
64”
[1626mm]
Minimum