CODE APPROVALS 

 

• 

This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L 

vent. May also be vented through a conventional chimney using a chimney liner kit. 
 
These appliances have been tested by Intertek Testing Services and found to comply with the established 
standards for a GAS FIRED VENTED ROOM HEATERS in CANADA and the USA as follows. 

 

LISTED GAS FIRED VENTED ROOM HEATER (EG 40 BV. Nat. & LPG. ) 

TESTED TO: ANSI Z21.11.1b-1995 GAS FIRED ROOM HEATERS.  ANSI Z21.50-1996/CGA-2.22-M96, 
VENTED GAS FIREPLACES.CAN 1-2.1-M86 GAS FIRED VENTED ROOM HEATERS. 

 

SPECS: 

ENVIRO EG 40 B VENT UNITS;

 

• 

Have all been certified for use with either natural or propane gases. (See control panel and rating label.) 

• 

Are not for use with solid fuels. 

• 

Must not be connected to a chimney flue serving a separate solid-fuel burning appliance. 

• 

Are approved for bedroom or bed-sitting room.   

 

(

IN CANADA

: must be installed with a listed wall thermostat) 

(

IN USA

: see current ANSI Z223.1 for installation instructions.) 

• 

Must be installed in accordance with local codes if any. If none exist, use current installation code CAN/CGA  
-B149 in Canada or ANSI Z223.1 / NFPA 54 in the USA. 

• 

Must be properly connected to an approved venting system. 

• 

Are approved for installation on combustible materials.  

• 

Are not approved for closet or installations. 

 

FOR INSTALLATIONS: ABOVE 2000 FEET (610 m). 

In Canada these appliances must have the input de-rated by 10% as per the gas code. 
In the USA these appliances must have the inputs de-rated by 4% for every 1000 feet (305m) above sea level.

 

 

ASSEMBLY INSTRUCTIONS 

 

• 

Remove the packaging from the appliance. Check to make sure there is no damage. If damage is found, 
please report it to both the carrier and your dealer as soon as possible. 

 

• 

Before beginning carefully inspect the door, glass and the log see for damage. 

 

• 

Do not use door and glass if the glass is damaged or broken.

 

Summary of Contents for EG 40 B

Page 1: ...ult causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use g...

Page 2: ...n must conform to local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent injurie...

Page 3: ...se with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be connected to a chimney flue serving a separate solid fuel burning appliance Are...

Page 4: ...e flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materials i...

Page 5: ...et 90cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 6 feet 1 8m minimum J Clearance to non mechanical air supply inlet to building or the combustion...

Page 6: ...A SEPARATE SOLID FUEL BURNING APPLIANCE FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROT...

Page 7: ...rding the suitability of your application For other special venting requirements please refer to the local state provincial or national codes For best venting performance we recommend total vent heigh...

Page 8: ...y important to install these logs in their proper position to insure safe optimum operating conditions Open the front door place logs on guide pins as per picture Close the door and tighten securely U...

Page 9: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Page 10: ...door fastener Using a 1 2 wrench loosen the fastener 2 Due to the shape of the bay window door You must also open the left hand side flap before attempting to open the door 3 Ensure the door is proper...

Page 11: ...essed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot w...

Page 12: ...Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON WARNOCK HERSEY RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Millivolt Ter...

Page 13: ...ipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle DO NOT cut or remove the grounding prong from the...

Page 14: ...Gold trim Package Low Voltage Thermostat REMOVING THE BLOWER 14 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between th...

Page 15: ...lot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITOR ELECTRODE DO NOT reuse the old pilot assembly gasket install the new gasket that is supplied STE...

Page 16: ...only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under thi...

Page 17: ...g Harness Complete 2 pieces 30 014 Freestanding Burner Control NG Complete EC 040 Freestanding Fan Control Knob 30 015 Freestanding Burner Control LP Complete EC 043 IEC Power Cord 30 017 Rear Burner...

Page 18: ...r 2003 EG40 GAS TRAY AND DOOR ASSEMBLIES Rear Venturi EG40 099 S I T Nova 820 Valve EC 006 NG EC 007 LPG S I T Piezo Ignitor EC 023 Burner Switch EC 025 Light Switch EC 066 FS Fan Controller EF 045 FS...

Page 19: ...Side Panel Cabinet EG40 086 Flue Pipe Freestanding Pedestal Wiring Plate Freestanding Pedestal Box Cover EG40 307 1x1 Side Cabinet Hinge EC 054 Freestanding Side Panel Cabinet EG40 086 Convection Air...

Page 20: ..._____ 20 Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ _____________________________________...

Reviews: