Enviro EG 40 B Owner'S Manual Download Page 17

 17

PARTS LIST 

 

EC-001 

120 

°

 F (49 

°

C) Ceramic Temperature 

Sensor 

EG40-086  

Freestanding Side Panel 

EC-002 

220 

°

F (104 

°

C) Ceramic Spill Switch 

EG40-087  

BV Stove Top 

EC-006 

S.I.T. NOVA Valve NG 

EG40-087A   DV Stove Top 

EC-007 

S.I.T. NOVA Valve LP 

EG40-088 

Firebox Baffle  

EC-009 

Thermocouple Post (10/00) 

EG40-089 

Front Burner 

EC-011 

Spark Electrode with Ignitor Wire 

EG40-091 

Stove Top Baffle BV 

EC-012  

Thermopile 

EG40-091A 

Stove Top Baffle DV 

EC-013 

Pilot NG with electrode 

EG40-098 

Front Venturi 

EC-014 

Pilot LP with electrode EG40-099 

Rear 

Venturi 

EC-015 

Fully Assembled Pilot NG 

EG40-120 

Freestanding Burner Gasket 

EC-016  

Fully Assembled Pilot LP 

EG40-123 

Window Channel Tape 72” 

EC-019 

Pilot Orifice (Injector) NG Threaded 

EG40-129 

Steel Brick Liner 

EC-020 

Pilot Orifice (Injector) LP Threaded 

EG40-135 

Freestanding Pedestal Door 

EC-021 

Pilot Gasket 

EG40-200 

LP to NG Conversion Kit 

EC-023 

S.I.T. Piezo Ignitor 

EG40-202 

NG to LP Conversion Kit 

EC-024 

S.S. Flex Connector with 3/8” Elbow 18” 
Long 

EG40-213  

Freestanding Ash Sill (post 3/00) 

EC-025 

Freestanding Burner Switch 

EG40-302 

Door Latch Strip Hinge (Set of 2) 

EC-031 

Miniature Light Bulb (115V) 

EG40-304 

Freestanding Fan Mount 

EC-032  

Light Bulb Holder 

EG40-307 

Freestanding Pedestal Box Cover 

EC-037 

Freestanding Wiring Harness Complete  
(2 pieces) 

30-014 

Freestanding Burner Control NG 
Complete 

EC-040 

Freestanding Fan Control Knob 

30-015 

Freestanding Burner Control LP 
Complete 

EC-043 

IEC Power Cord 

30-017 

Rear Burner (Post 2000) 

EC-045 

Embers 

30-040 

EG 40 Right Log 

EC-053 

Tapped Corner Bracket 

30-041 

EG 40 Left Log 

EC-054 

1 X 1 Side Cabinet Hinge 

30-042 

EG 40 Rear Log 

EC-056 

Freestanding Pedestal Door Magnet  

30-043 

Pilot Line with Brass Ferals 

EC-057 

3/8” Tadpole Door Gasket (6.9ft) 

50-081  

EG 40 Log Set Complete 

EC-058 

Window Channel Tape 

50-343 

Blank Orifice – Front 

EC-059 

Door Latch Bolt 

50-345 

Freestanding Pilot Tubing and Fittings 

EC-060 

Simpson Duravent GS Adapter 

50-478 

Freestanding Bar Set - Nickel 

EC-066 

Freestanding Light Switch 

EG40-115 

Freestanding Bar Set - Gold 

EC-067 

Vent Restrictor Ring 

50-480 

Outer Door Cover (A) - Gold 

EF-045 

Freestanding Fan Controller 

50-481 

Outer Door Cover (A) - Nickel 

EG40-023 

Latch Bracket & Nut 

50-776 

Outer Door Cover (A) - Painted 

EG40-033 

Convection Air Deflectors 50-514 

Convection 

Blower 

EG40-049 

Freestanding Side Panel Magnets 

50-652 

16” Ignitor Cable 

EG40-066 

Fan Access Cover Gasket 

50-713 

IEC Power Cord Outlet 

EG40-070 

Freestanding DV Owner’s Manual 

50-774 

Burner Tray Top Freestanding NG  
(Post 2000) 

EG40-071 

Freestanding BV Owner’s Manual 

50-775 

Burner Tray Top Freestanding LP  
(Post 2000) 

EG40-077 

Complete Inner Door with glass 

 

 

EG40-078 

Beveled Panel - 40” x 28” 

 

 

EG40-079 

O/S Beveled Panel - 46” x 33” 

 

 

EG40-080 Freestanding 

Pedestal 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EG 40 B

Page 1: ...ult causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use g...

Page 2: ...n must conform to local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent injurie...

Page 3: ...se with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be connected to a chimney flue serving a separate solid fuel burning appliance Are...

Page 4: ...e flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materials i...

Page 5: ...et 90cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 6 feet 1 8m minimum J Clearance to non mechanical air supply inlet to building or the combustion...

Page 6: ...A SEPARATE SOLID FUEL BURNING APPLIANCE FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROT...

Page 7: ...rding the suitability of your application For other special venting requirements please refer to the local state provincial or national codes For best venting performance we recommend total vent heigh...

Page 8: ...y important to install these logs in their proper position to insure safe optimum operating conditions Open the front door place logs on guide pins as per picture Close the door and tighten securely U...

Page 9: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Page 10: ...door fastener Using a 1 2 wrench loosen the fastener 2 Due to the shape of the bay window door You must also open the left hand side flap before attempting to open the door 3 Ensure the door is proper...

Page 11: ...essed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot w...

Page 12: ...Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON WARNOCK HERSEY RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Millivolt Ter...

Page 13: ...ipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle DO NOT cut or remove the grounding prong from the...

Page 14: ...Gold trim Package Low Voltage Thermostat REMOVING THE BLOWER 14 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between th...

Page 15: ...lot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITOR ELECTRODE DO NOT reuse the old pilot assembly gasket install the new gasket that is supplied STE...

Page 16: ...only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under thi...

Page 17: ...g Harness Complete 2 pieces 30 014 Freestanding Burner Control NG Complete EC 040 Freestanding Fan Control Knob 30 015 Freestanding Burner Control LP Complete EC 043 IEC Power Cord 30 017 Rear Burner...

Page 18: ...r 2003 EG40 GAS TRAY AND DOOR ASSEMBLIES Rear Venturi EG40 099 S I T Nova 820 Valve EC 006 NG EC 007 LPG S I T Piezo Ignitor EC 023 Burner Switch EC 025 Light Switch EC 066 FS Fan Controller EF 045 FS...

Page 19: ...Side Panel Cabinet EG40 086 Flue Pipe Freestanding Pedestal Wiring Plate Freestanding Pedestal Box Cover EG40 307 1x1 Side Cabinet Hinge EC 054 Freestanding Side Panel Cabinet EG40 086 Convection Air...

Page 20: ..._____ 20 Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ _____________________________________...

Reviews: