background image

MAINTENANCE AND TECHNICAL 

 
 

Periodically check to ensure that your "Direct Vent" 
system is clear. 

 

Periodically check the pilot and burner.  Check to see 
that all the burner ports are clean and clear.  Check 
the pilot head for blockage.  Check to ensure the pilot 
flame is blue with small yellow tips. 

 

OPENING THE DOOR

 

 

Caution

 door is hot when in operation. 

 
1.  Open the right hand hinged side flap, which will 
expose a door fastener.  Using a 1/2" wrench, loosen 
the fastener.

 

 

2.  Due to the shape of the bay window door. You 
must also open the left-hand side flap before 
attempting to open the door. 

 
CLEANING OF GLASS 

 

Do not clean glass when hot 

 
It will be necessary to clean the ceramic glass 
periodically.  During a cold start up, condensation will 
sometimes form on the glass, this is a normal 
condition with all gas fireplaces and stoves.  However, 
this condensation can allow dust and lint to cling to the 
glass surface. Initial paint curing of the appliance can 
leave behind a slight film on the glass.  This is a 
temporary problem. It is therefore recommended that 
the glass be cleaned initially after about the first two 
weeks of use.

 

 

After that, depending upon the amount of use, 
cleaning should be required no more than two or three 
times per season. 

 

To clean the door, use a mild glass cleaner and a soft 
cloth.  Abrasive cleaners will damage the glass and 
gold surfaces.  Close door tightly. 

 

TO REPLACE DOOR AND GLASS ASSEMBLY 

 

The glass in this appliance is an integral part of the 
door assembly.  If the glass is damaged or broken a 
replacement door assembly including glass must be 
fitted. 

 

To Replace: 

• 

open door fully 

• 

Lift door vertically so that hinge pins lift out of 
hinge receivers. 

• 

Return the door assembly to dealer. 

Door and glass assembly must be replaced as a 
complete unit by your ENVIROGAS Dealer. 
 No substitute materials are allowed.

 

 

FOR CLEANING THE INSIDE OF THE FIREBOX 

 
Remove the log carefully from the firebox.  Gently 
remove the embers and place on a piece of paper 
towel, until ready to replace.

 

 

Vacuum the firebox thoroughly.  Carefully clean off 
any dust on the logs and remove any lint from the 
main burner and pilot burner. 

 

After carefully replacing the log and embers in their 
correct positions, and the door has been resealed, re-
light the pilot, following the instructions on the attached 
label. 

 

CLEARANCES MUST BE SUFFICIENT TO ALLOW 
ACCESS FOR MAINTENANCE AND SERVICE 
 

 

 

16

Summary of Contents for EG 28

Page 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is n...

Page 2: ...stallation must conform to local codes or in the absence of local codes with the current CAN 1 B 149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent...

Page 3: ...tural or propane gases see control panel and rating label are not for use with solid fuels must not be connected to a chimney flue serving a separate solid fuel burning appliance are approved for bedr...

Page 4: ...re the flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materia...

Page 5: ...to a mechanical air supply inlet 6 feet 1 8m minimum L Clearance above paved side walk or paved driveway located on public property 7 feet 2 1m minimum M Clearance under verandah porch deck or balcony...

Page 6: ...HE OUTSIDE VENT TERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENGTH DIAGRAM PRECISELY...

Page 7: ...shown in FIG 10 NOTE 1 Twist lock procedure four indentations located on the female end of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by o...

Page 8: ...excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff shaded area in FIG 12 so that an air...

Page 9: ...pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections h...

Page 10: ...quired at the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the fir...

Page 11: ...ide on a location for the unit that will meet any or all local code requirements Refer to sections in this manual Deciding Were To Locate Your Stove and Planning Your Installation Set the appliance in...

Page 12: ...liner over collar secure the flex liner with 3 sheet metal screws evenly spaced Align all straight sections of pipe slipping all joints together and installing 3 sheet metal screws evenly spaced A sm...

Page 13: ...minimum 4 flex liner to the top of the CLASS A chimney Placing a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter Secure the cap adapter t...

Page 14: ...EVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED INSTALLING THE LOGSET INSTALLING THE LOGSET Carefully remove log from box Check to ensure there is no damage It is very important to install this log...

Page 15: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Page 16: ...about the first two weeks of use After that depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a sof...

Page 17: ...thermocouple Air in gas line Pilot flame dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pres...

Page 18: ...ition of the National Fuel Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap M...

Page 19: ...d securely to the floor WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a pro...

Page 20: ...ower does not require lubrication 20 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Li...

Page 21: ...ided by S I T STEP 5 To change the pilot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrenc...

Page 22: ...rts only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under...

Page 23: ...143 BURNER COMPLETE W NOVA SIT VALVE NG EC 024 SS FLEX CONNECTOR WITH 3 8 ELBOW 18 LONG EG28 145 BURNER COMPLETE W NOVA SIT VALVE LP EC 025 BURNER SWITCH FOR NOVA TRAY EG28 150 ASH SILL EC 029 FAN ACC...

Page 24: ...ET FS CABINET SIDE PANEL EG28 123 BV TOP BAFFLE EG28 132 DV TOP BAFFLE EG28 131 FS CABINET SIDE PANEL EG28 123 BV 4 CRIMPED FLUE PIPE EG28 169 DV 4 FLARED FLUE PIPE EG28 170 120 F 49 C CERAMIC FAN TEM...

Page 25: ...LASS A B EG28 101 BURNER CONTROL ASSEMBLY COMPLETE EG28 143 NG EG28 145 LPG FULLY ASSEMBLED PILOT EC 015 NG 016 LP THERMOPILE EC 012 THERMOCOUPLE EC 009 PILOT ORIFICE EC 019 NG 020 LP SPARK ELECTRODE...

Page 26: ..._______________________ Phone ___________________________________ Name of Installer ___________________________________________ Address _________________________________________ __ ___________________...

Reviews: