background image

HIGH-EFFICIENCY - MULTI SOLID FUEL  

CENTRAL-HEATING STOVE WITH AUTOMATIC CONTROL 

ISSUED - 10/09/2013 (456)

PLEASE LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER

DB15

INSTALLATION AND OPERATING INSTRUCTIONS

Summary of Contents for DB15

Page 1: ...HIGH EFFICIENCY MULTI SOLID FUEL CENTRAL HEATING STOVE WITH AUTOMATIC CONTROL Issued 10 09 2013 456 PLEASE LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER DB15 INSTALLATION AND OPERATING INSTRUCTIONS ...

Page 2: ...h timber thatch or other vulnerable materials take specialist advice It is not possible to access the chimney for cleaning through the stove inspection and sweeping access must be provided The chimney must Generate a draught in use of at least 12Pa 0 05ins wg Be capable of withstanding the temperatures generated Be absolutely incapable of leaking fumes into the dwelling Several different forms of ...

Page 3: ...r manufactured smokeless fuels then empty the ash regularly if it builds up it will severely damage the grates If you mainly use wood then do the opposite let the ash and charcoal build up To empty the ash agitate the firebed by using the tool to operate the riddling mechanism on the right hand side Use the ashpan tool to lift out the ashpan Remember to let ash cool before disposing in plastic sac...

Page 4: ...himney Checktherequirementsearlier in this document and in any case of doubt engage a professional sweep or chimney engineer POOR AIR SUPPLY Lack of air to the fire is a common cause of smoking and poor performance Air supply problemsmaybe worseincertain wind conditions often incorrectly ascribed to downdraught which is in fact very rare where air can be sucked out of the room The answer is to fit...

Page 5: ...hemselves Systems must 1 CONTROL THE HEATING SYSTEM Stove boilers control their own water temperature by an internal thermostat so controls such as time clocks and thermostats regulate flow through the heating circuit not the boiler 2 GUARD AGAINST CONDENSATION Solid fuels contain water which can condense on cool boiler faces to cause VERY rapid corrosion and failure Use very dry fuel and always f...

Page 6: ...ratures are approximate and will vary Scheme 1 TRADITIONAL 2 SIDE Compact and quick to heat Stores hot water for taps but radiators will go cold if the fire goes out Recommended for occasional use or where long burning mineral fuels are used One side of the boiler feeds by gravity circulation alone an indirect coil to heat a hot water storage cylinder and has feed and vent connections to a small o...

Page 7: ... 8 5 7 6 2 7 8 9 1 To water kW 6 3 8 8 7 9 7 7 7 6 Total Output kW 12 1 14 5 4 1 15 5 16 7 Mean Flue Gas Temp Rise ºC 200 C 263 C 251 C 276 C 241 C CO 13 o2 0 06 0 24 0 07 0 24 0 23 Minimum room air entry requirement 8000 mm Minimum Clearance to combustibles 100mm at sides and back Temperature underneath can exceed 100 C traditional hearth required These stoves exceed the safety and performance re...

Reviews: