Floor Protection
C
B
A
C
LEARANCES
TO
C
OMBUSTIBLES
:
Maintain these clearances to combustibles.
A) SIDE WALL TO UNIT
6 INCHES (153 mm)
B) BACK WALL TO UNIT
1 INCHES ( 25 mm)
C) ADJACENT WALL TO CORNER OF UNIT
1 INCHES ( 25 mm)
- MANTLE (HEARTH MOUNT)
8 INCHES (203 mm)
Installation
A
LCOVE
C
LEARANCES
:
This unit may be installed in an alcove. Maintain
clearances to combustibles.
MIN. ALCOVE WIDTH
36 INCHES ( 914 mm)
MIN. ALCOVE HEIGHT
48 INCHES (1220 mm)
MIN. ALCOVE DEPTH
30 INCHES ( 762 mm)
Install vent at clearances specified by
the vent manufacturer.
This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example
linoleum, hardwood flooring). If combustible flooring is underneath the unit 6 inches (153 mm) on either
side and to the front must be protected by non-combustible material. If this unit is to be installed onto
a carpeted surface, a hearth pad must be used for stability.
30
" (
75
cm
)
48"
(120cm)
36" (90cm)
Figure 13