Enviro DRIFTWOOD E33 Owner'S Manual Download Page 8

Operating Instructions

8

Figure 4.  Pilot Flame

P

iLot

 L

ight

:

1. Turn off the gas to the fireplace.  

If not recently done, remove the 

glass  and  let  the  unit  air  out  for  at  least  five  (5)  minutes  to 

clear out any gas. 

Turn on gas to the heater. Leak test all joints with 

soapy water. 

NEVER USE OPEN FLAME FOR LEAK TESTING.

 

2. Start the pilot by pressing the gas control knob and turning it to PILOT.  

While holding the gas control knob in, press the piezo ignitor several 

times  until  the  pilot  light  starts.  Hold  the  gas  control  knob  in  for  30 

seconds.  Check  that  the  pilot  has  fully  engulfed  the  thermocouple 

assembly (see Figure 4).

3. Start the main burner by turning the gas control knob to ON and then 

turn the rocker switch to ON. Check that all burner ports have flame.

4. Leak test all gas joints again.

n

oRmaL

 s

ounDs

 D

uRing

 o

PeRation

:

Component

Sound & Reason

Fire Box

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increases and decreases with the speed of the blower.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

Table 2: Normal Sound

V

entuRi

 a

Djustment

:

Thermopile

Thermocouple

Warning:

 Incorrect  venturi adjustment may lead to improper combustion, which is a safety hazard. 

Contact the dealer if there is any concern about the venturi adjustment.

Figure 5: Adjusting the venturi air setting.

The venturi adjustment lever is located on the right side of the unit, behind the surround panel (see 

Figure 5).  To avoid touching hot surfaces under the unit, use the Door Tool to adjust the venturi. 
The venturi allows the amount of air coming into the fireplace to be adjusted in order to accommodate 

different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot 

flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly 

fifteen (15) minutes and then examine the flames.  The 

ideal flame will be blue at the base and light orange 

above. The flames should be of medium height.  If the 

flames look like this, no venturi adjustment is needed. If 

the flames are fairly short and mostly blue, the fireplace 

is getting too much air. Therefore, the air shutter should 

be closed (push in) slightly until the correct flames are 

achieved.  Flames that are very orange, with tall dark 

stringy tips are not getting enough air.  Open (pull out) 

the venturi until the flames clean up.  If the venturi is 

opened,  then closed all the way, and the correct flames 

cannot be attained, turn off the gas and contact the 

dealer.

Summary of Contents for DRIFTWOOD E33

Page 1: ...ertible for use with other gases unless a certified kit is used WHAT TO DO IF YOU SMELL GAS Open windows extinguish any open flame Do not try to light any appliance Do not touch any electrical switch...

Page 2: ...the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the National Gas and Propane Installation Code CSA B149 1 To prevent injury do not allow anyone who is unfamiliar wit...

Page 3: ...g Valve Cover 12 Fuel Conversion 12 Initial Installation 15 Clearances to Combustibles 15 Minimum Fireplace Size 15 Direct Vent Model 15 Preparing Your E33 For Installation 16 Venting Fireplace Insert...

Page 4: ...TING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO E33 Fireplace Insert Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels...

Page 5: ...on The rating label is located on the left side of the unit next to the fan controller Dimensions 5 Figure 1 E33 Exterior Dimensions 33 00 28 89 27 05 16 64 18 55 25 14 05 11 24 22 16 9 06 9 09 19 78...

Page 6: ...Surround Extruded Surround Height 26 5 673 mm 26 5 673 mm 26 5 673 mm Width 44 1 8 1121 mm 44 1 8 1121 mm 44 1 8 1121 mm Trimmable Surround Height Width 38 965mm 46 1168mm Base Shelf Base Shelf Riser...

Page 7: ...next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any pho...

Page 8: ...ng and closing Table 2 Normal Sound Venturi Adjustment Thermopile Thermocouple Warning Incorrect venturi adjustment may lead to improper combustion which is a safety hazard Contact the dealer if there...

Page 9: ...Flip the burner switch to OFF to turn off burner only If the fireplace is to be turned off for the season or for servicing turn control knob to OFF turn the gas shut off valve to OFF DO NOT FORCE IT...

Page 10: ...ll the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and remove any lint from the burner and pilot At this time insp...

Page 11: ...er operate the fireplace with the glass removed Caution glass may Separate from door Figure 8 Door Release Figure 9 Door Removal Remove the glass door by placing the hooked end of the door release too...

Page 12: ...Service Removing Valve Cover The valve cover can be removed to access the gas valve 1 Use a T 20 screwdriver to remove the eight screws that hold down the valve cover shown in Fig 10 Figure 10 Valve...

Page 13: ...gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion Allow the valve and unit to cool down to room temperature 2 Remove the glass as shown...

Page 14: ...ure 11 MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type Figure 14 O ring on valve screw Figure 15 I...

Page 15: ...for E33 to be installed into Width At Front Width At Back Height Depth Fireplace Dimensions 32 813 mm 20 508 mm 20 508 mm 16 406 mm NOTE Space must be provided for gas line on right side of unit for...

Page 16: ...d in accordance with the National Provincial State and local building codes and has been constructed of non combustible materials Before starting refer to Initial Installation Preparing Your E33 For I...

Page 17: ...eight of the chimney Every joint in the venting must be secured with three 3 8 x 3 8 HWH sheet metal screws and an appropriate sealant either silicone or stove cement The flue damper can be fully bloc...

Page 18: ...ed down and folded over 5 Apply a bead of stove cement sealant to the top section of the 3 76mm exhaust vent collar plate Slide the 3 76mm flex vent over the flue collar and secure with three 3 sheet...

Page 19: ...stove above the door opening see Figure 21 Slide the collar plate backwards Properly secure the vent collar plate to the flexible vent pipe liner s previously installed in the chimney Be careful not t...

Page 20: ...THIS CONDITION IMPORTANT If the factory built fireplace has no gas access hole s provided an access hole of 1 5 inch 37 5 mm or less may be drilled through the lower sides or bottom of the firebox in...

Page 21: ...s For Electrical Installations or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong groundin...

Page 22: ...tion after the gas supply line has been installed A shut off valve is supplied with this unit The appliance and its appliance main gas valve must be disconnected from the gas supply piping system duri...

Page 23: ...hose and tighten set screw 6 Re install the knobs Pointer on knobs can be removed and oriented correctly to point at the right location Always check for gas leaks with a soap and water solution after...

Page 24: ...should the need arise follow Steps 1 2 below Figure 28 Proper Pilot Flame 3 8 1 2 10 13mm Thermocouple Proper Flame Adjustment Initial Installation QUALIFIED INSTALLERS ONLY 1 The adjustment screw can...

Page 25: ...el options and it may also be used with the E33 Trimmable Surround The Base Shelf and Riser are sold separately Installation 1 If unit is running turn it off and allow it to cool completely 2 When usi...

Page 26: ...ner appearance 4 Cut along the preferred line from direct measurements of offset and remove any sharp edges 5 The panel can be touched up with a high temperature metallic black paint available from yo...

Page 27: ...panel over the corresponding screws on top of the stove and at the bottom of the stove on each side see Figure 33 Ensure the panel is secure before releasing it The bottom screws can be tightened on...

Page 28: ...fully remove the front brick panel on the bottom of the firebox by lifting it up Figure 36 The side brick panels can be removed by pulling them towards the center of the firebox Secondary Installation...

Page 29: ...of the back log Figure 41 Place the ember bed in the center of the burner tube and pull it forward as far as it will go Ensure it does not obstruct any part of the burner WARNING Failure to position...

Page 30: ...rregularly onto and around the front of the burner to create a realistic look WARNINGS DO NOT pack this ember material as this could create an unsafe condition The pieces should be lightly placed so t...

Page 31: ...the glass and rearrange the ember material making sure none of the burner port holes are blocked Never operate the fireplace with the glass door removed Figure 45 Sixth Stage Log Set Installation Fig...

Page 32: ...ouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not re...

Page 33: ...Burner Switch EC 026 6 Pilot Shield 50 2500 7 Valve Extension C W Knob Long 50 2519 8 FPI Fan Controller 69 5V 115V W FS Knob EC 039A 9 Fan Controller Knob W Decal EC 040 10 Control Panel C W Decal 5...

Page 34: ...Can of Metallic Black Touch Up Paint PAINT 12 MB 24 Pilot Assembly 50 2513 Reference Number Option Description Part Number 25 Regular Surround Panel E33 50 2428 26 Contemporary Surround Panel E33 50...

Page 35: ...Parts Diagram Components 35 18 19 20 21 22 23 24...

Page 36: ...Parts Diagram Options 36 26 27 28 30 29 25 31...

Page 37: ...1 Year Warranty Under this warranty Sherwood Industries Ltd covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labour for the...

Page 38: ...offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 12 The Limited Warranty is void if a The stove has been operated in atmosphere...

Page 39: ...e for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 28 At no time will Sherwood I...

Page 40: ...______________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT...

Reviews: