G
ENERAL
S
ELECTION
, PSC M
OTOR
• CFR
©December, 2005 Environmental Technologies, Inc.
• CFR Catalog
13
DIS.
0.5"
1.0"
3.0"
LOW MED HI LOW MED HI LOW MED HI LOW MED
HI
1100
0.04
1.10
21
31
36
43
1400
0.06
1.10
26
37
40
46
1700
0.09
1.03
29
39
42
48
2000
0.12
0.82
32
43
46
52
2300
0.17
0.56
35
48
48
55
1100
0.02
1.10
21
31
36
43
1400
0.04
1.10
26
37
40
46
1700
0.07
1.03
29
39
42
48
2000
0.08
0.82
32
43
46
52
2300
0.11
0.56
35
48
48
55
2600
0.14
0.25
37
51
51
55
1100
0.04
0.90
--
26
27
33
1500
0.05
0.85
20
30
31
38
1900
0.09
0.78
23
33
35
40
2300
0.12
0.68
27
38
38
43
1100
0.03
0.90
--
26
28
32
1500
0.05
0.85
20
30
31
38
1900
0.07
0.78
23
35
36
41
2300
0.10
0.68
27
37
38
43
2700
0.13
0.56
30
40
40
46
3100
0.18
0.40
33
42
43
50
1500
0.02
0.85
20
30
31
38
1900
0.04
0.78
23
32
35
40
2300
0.06
0.68
27
36
38
42
2700
0.08
0.56
30
38
40
45
3100
0.10
0.40
33
41
42
47
1600
0.06
0.90
--
26
28
37
2100
0.10
0.90
22
31
33
41
2600
0.14
0.87
26
36
37
45
3100
0.20
0.80
31
41
42
47
1600
0.04
0.90
--
27
31
38
2100
0.07
0.90
22
31
33
41
2600
0.11
0.87
26
35
38
43
3100
0.15
0.80
31
41
42
47
3600
0.21
0.66
34
45
45
50
4100
0.28
0.40
38
50
50
53
2100
0.05
1.10
21
30
32
40
2600
0.09
1.10
25
33
36
42
3100
0.12
1.00
28
38
39
45
3600
0.17
0.88
32
42
43
48
4100
0.22
0.62
36
46
46
51
2100
0.10
1.10
21
27
34
43
2600
0.15
1.10
25
31
37
45
3100
0.22
1.00
28
36
40
46
3600
0.30
0.88
32
40
42
48
4100
0.44
0.62
36
43
45
52
4600
0.56
0.33
39
50
50
56
10.6
5.6
3.6
8.0
5.4
4.6
5.0
6.4
8.4
UNIT
SIZE
1224
1424
1230
1844
17.8
1.0
(2)
3/4
(2)
1/2
(2)
277V
FAN HP
9.0
7.6
6.8
24.6
22.0
3/4
(2)
18.8
1/3
(2)
HORSEPOWER / AMPERAGE DATA
21.0
7.2
7.4
8.6
AMPERAGE
115V
1/3
(2)
1/4
(2)
208V
1/2
(2)
19.2
18.6
17.6
1/2
(2)
20.6
1440
1640
1644
1844
1630
1224
1424
1230
1430
INLET
ΔΔ
Ps
MIN.
Δ
Ps
(IN. W.G.)
RADIATED
UNIT
SIZE
CFM
MAX
E.S.P.
(IN. W.G.)
ROOM NOISE CRITERIA (NC)
FAN
ONLY
4.5
7.2
5.8
5.6
11.0 12.3
3.4
3.8
1.8
2.8
5.3
1/2
3/4
1.0
8.9
1430
1440
1640
1644
1630
The ENVIRO-TEC
®
Windows
®
based Computer Selection Program is available through your ENVIRO-TEC
®
representative for
complete CFR selection and performance data.
NOTES:
• Min.
Δ
Ps is the static pressure difference across the primary air valve with
the damper wide open. All downstream losses (including optional hot
water coil) are handled by the unit fan and need not be considered for
primary air performance calculations.
• Max. E.S.P. is the external static pressure available on high tap at the
airflow capacity indicated. Optional hot water coil pressure loss is not
included with these values.
• Performance data obtained from tests conducted in accordance with ARI
Standard 880.
• Dash (-) indicates NC level less than 20.
• NC values calculated based upon the 2002 Addendum to ARI Standard
885 Appendix E
Typical Sound Attenuation Values
(shown at right),
using Ceiling Type 2 for calculating Radiated NC.
2
3
4
5
6
7
Small Box (< 300 CFM)
24 28 39 53 59 40
Medium Box (300-700 CFM)
27 29 40 51 53 39
Large Box (> 700 CFM)
29 30 41 51 52 39
2
3
4
5
6
7
Type 2 - Mineral Fiber Ceiling 18 19 20 26 31 36
OCTAVE BAND
OCTAVE BAND
RADIATED
ATTENUATION VALUES
DISCHARGE
ATTENUATION VALUES
Shaded Unit Sizes (i.e. 1430, 1640) indicate the most commonly specified selections.