WARNING:
Only persons licensed to work with gas piping may make the necessary gas connections to
this appliance.
GAS LINE CONNECTION
•
This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in
a 3⁄8” male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation
code in Canada, or in the USA gas installations follow either local codes or the current edition of the
National Fuel Gas Code ANSI Z223.1.
•
The efficiency rating of this appliance is a product thermal efficiency rating determined under
continuous operating conditions and was determined independently of any installed system.
The appliance and its shutoff valves must be
disconnected from the gas supply piping system
during any pressure testing where the pressure
exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur
to the valve.
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1⁄2 psig (3.45 KPa).
Always check for gas leaks with a soap
and water solution after completing the
required pressure test.
TO TEST VALVE PRESSURES
The pressure taps are located on the left side of the valve
•
Turn set screw 1 turn counter clockwise to loosen,
•
Place
5
/
16
” (8 mm) I.D. hose over pressure tap system.
•
Check pressures using a manometer.
•
When finished, release pressure, remove hose & tighten set screw.
Table 6: Pressure and BTU Information.
Natural Gas
Propane
Main Burner
#48 DMS
#57 DMS
Manifold Pressure
3.8” W.C. / 0.95KPa
11.0” W.C. / 2.7KPa
Min. Manifold Pressure
1.1” W.C. / 0.27KPa
2.7” W.C. / 0.67KPa
Max Supply Pressure
7.0” W.C. / 1.74KPa
13.0” W.C. / 3.28KPa
Min. Supply Pressure
5” W.C. / 1.24KPa
12.0” W.C. / 2.98KPa
Max BTU/hr Input
17,000 BTU/hr / 4.98KW
16,000 BTU/hr / 4.68KW
Min. BTU/hr Input
10,000 BTU/hr / 2.93KW
8,000 BTU/hr / 2.34KW
NEVER USE AN OPEN FLAME FOR LEAK TESTING.