background image

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY  
THIS MANUAL IS PRINTED ON RECYCLED PAPER 

              8 2 8

 

 

 

 

  B y   S H E R W O O D   I N D U S T R I E S   L T D .  

    B   V e n t

 

O W N E R S   M A N U A L

 

Installation And Operating Instructions For Models: 

 

828 BV. FS. (Freestanding) 

 

828 BV. INS. (Insert)

 

 

 

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

 

WHAT TO DO IF YOU SMELL GAS 

 Open windows/Extinguish any open flame 

 Do not try to light any appliance. 

 Do not touch any electrical switch; do not use any 

phone in your building. 

 Immediately call your gas supplier from a 

neighbor's phone.    Follow the gas supplier's 
instructions. 

 If you cannot reach your gas supplier, call the fire 

department.

 

WARNING

 

If the information in this 

manual is not followed exactly, 

a fire or explosion may result 

causing property damage, 

personal injury or loss of life. 

Installation and service must 

be performed by a qualified 

installer, service agency or the 

gas supplier. 

FOR YOUR SAFETY 

Do not store or use gasoline or other Flammable vapors and liquids 

 in the vicinity of this or any other appliance.

 

Summary of Contents for 828 BV. INS.

Page 1: ...pliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Insta...

Page 2: ...s installation must conform with local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To prevent injury do not allow anyone who is unfamiliar with the operation to use the stove Always keep the area around these appliances clear of combustible material gasoline or other flammable vapors and liq...

Page 3: ...r GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows ENVIROGAS 828 VENTED ROOM HEATER 828 BV FPI Nat LPG 828 BV FS Nat LPG TESTED TO ANSI Z21 11 1b 1993 CAN 1 2 1M 86 2 SPECIFICATIONS ENVIROGAS 828 VENTED ROOM HEATER This unit must be vented using certified B Vent venting has been certified for use with either natural or propane gases see rating label is not for use with solid fuels is ...

Page 4: ...d system 3 DIMENSIONS AND CLEARANCES TO COMBUSTIBLES FIREPLACE INSERT CLEARANCES TO COMBUSTIBLES A Mantle pillar to stove 10 25 cm B Stove top to 8 wide mantle 12 31 cm Stove must sit on a non combustible surface the width and depth of the insert Maintain sufficient clearances for operation service and maintenance OTHER DIMENSIONS A Depth of unit into fireplace 11 28 5 cm B Depth of unit out of fi...

Page 5: ...window or door that may be opened 12 inches 30cm minimum C Clearance to permanently closed window minimum 12 inches 30cm recommended to prevent condensation on window D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60cm from the center line of the terminal 24 inches 60cm minimum E Clearance to unventilated soffit 18 inches 45cm minimum F ...

Page 6: ... damage is observed do not use unit and contact your local dealer 4 Remove the vent collar plate from the top of the stove by unscrewing the T20 Torx screw located on the center top of the stove and slide backwards SEE FIGURE 4 Properly secure the vent collar plate to the approved flexible pipe liner previously installed in the chimney Be careful not to over stretch the liner Figure 5 5 Place the ...

Page 7: ...MBLING YOUR ENVIROGAS 828 FREESTANDING APPLIANCE 1 Open the two hinged side panels open the door 2 Remove log and ember set and all wrapping material from the stove Check for damage If damage is observed do not use unit and contact your local dealer 3 Remove the two wood screws that secure the stove to the pallet these are located through the square openings inside the side panels 4 Place the stov...

Page 8: ...Efficiency and heat output of the unit increases with the operation of the fan This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug The appliance when installed with optional blower must be electrically connected and gro...

Page 9: ...ure tests ORIFICE SIZES PRESSURES AND BTU S The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system All models are equipped with a variable output gas control NATURAL GAS PROPANE ORIFICES Front Rear 51 DMS 49 DMS 59 DMS 56 DMS Manifold Press 3 5 wc 0 87 kPa 10 0 wc 2 49 ...

Page 10: ... or stainless steel flex vent and or certified 4 Type B Gas Vent The flue collar of the appliance will fit inside of a standard 4 vent and may be fastened directly to the vent Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation WARNING Operation of this heater when not connected to a properly installed and maintained venting system or tam...

Page 11: ...This stove should be vented by certified 4 Type B Gas Vent that may be encased in 6 decorative stovepipe The flue collar of the appliance will fit inside of standard vent and should be fastened directly to the vent The ENVIROGAS incorporates its own internal draft hood so no additional external draft hood is required The venting system should be assembled and installed according to the vent manufa...

Page 12: ...should be a minimum of 3 ft 62m from the top of the unit before any horizontal For other special venting requirements please refer to the local state provincial or national codes The bottom of the vent cap shall extend at least 2ft 6m above the highest point of the roof where it passes through and at least 2ft 6m higher than any portion of the roof within a horizontal distance of 10ft 3m See Figur...

Page 13: ...a single row of embers on top of the front burner Figure 16 Figure 16 2 Carefully avoid any clumping or large build ups Do not pack down leave embers loose 3 DO NOT PLACE EMBERS ON THE REAR BURNER 4 Upon the first light up watch for ignition to all burner ports If a long delay is noted a First wait for the appliance to cool down b Open the front door of the appliance c Carefully reposition the emb...

Page 14: ...trol knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clockwise to PILOT 7 Push the gas control knob in fully and hold ...

Page 15: ...fter cleaning before attempting to re light the appliance TO REPLACE DOOR AND GLASS ASSEMBLY The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitted To Replace open door fully Lift door vertically so that hinge pins lift out of hinge receivers Return assembly to dealer The Door and glass assem...

Page 16: ...ck gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot will not stay lit check thermopile for a Minimum of 300 mV when burner switched on Check wiring to thermostat for breaks Check for spillage at draft hood that may trip spill switch Flame lifting Leak in vent pipe Improper...

Page 17: ...44 Nova Pilot W Ignitor Electrode LP 828 030 Log Set Embers 828 045 3 8 Plastic Bushing 828 046 7 8 Plastic Bushing 828 054 Hi Temperature Electrical Cord 828 072 3 8 Tadpole Door Gasket 828 076 Envirogas Name Plate 828 077 120 Ceramic Auto Reset n o Temp Sensor big foot 828 078 220 Temp Sensor n c 828 079 SS Flex Connector with 3 8 Elbow 18 long 828 081 Fan Switch Plug 828 083 Freestanding Side C...

Page 18: ...nst flaking This offer includes parts and labor for 1 year and for parts only thereafter Your dealer shall make all claims under this warranty in writing A TO A MAXIMUM OF SEVEN YEARS WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM To the Dealer Name address and telephone number of purchaser and date of purchase Date of installation Name of...

Page 19: ...___________ Name of Installer ___________________________________________ Address ___________________________________________ ___________________________________________ ___________________________________________ Phone _____________________________________ Model ___________________________________ Serial Number __________________ Date of Purchase __________ ________ ________ Date of Installation ...

Page 20: ...20 ...

Reviews: