Step 7:

Ensure that the vent length is correct, and the venting is not crimped or overstretched.

Step 2:

Determine the best location on the exterior wall of the chimney for the vent terminal. Use Figure 3 as 

reference for the maximal and minimal vertical venting run.

1 OF 1

SHEET

Part Description

FINISH

SCALE- NOT TO SCALE

HEAT TREATMENT

Sherwood Industries Ltd.

MATERIAL

UNLESS OTHERWISE SPECIFIED

+/- .002

Hole Pos.

+/- .5

Angles

+/- .005

General

DIMENSIONS APPLY AFTER PLATING OR

HEAT TREATMENT

THREADS  EXTERNAL CL 2A  INTERNAL CL 2B

TOLERANCE

ALL DIMENSIONS IN INCHES

+/- .001

Hole Size

APPROVAL

CHECKED BY

DRAWN BY

THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.

10/4/2018

REV

Roughly 6-3/4”

Roughly 

5-3/4”

NOTE: Holes are 

orientated at a 40 

degree angle

Roughly 5”

3” Dia.

4” Dia.

Exterior View

1 OF 1

SHEET

Part Description

FINISH

SCALE- NOT TO SCALE

HEAT TREATMENT

Sherwood Industries Ltd.

MATERIAL

UNLESS OTHERWISE SPECIFIED

+/- .002

Hole Pos.

+/- .5

Angles

+/- .005

General

DIMENSIONS APPLY AFTER PLATING OR

HEAT TREATMENT

THREADS  EXTERNAL CL 2A  INTERNAL CL 2B

TOLERANCE

ALL DIMENSIONS IN INCHES

+/- .001

Hole Size

APPROVAL

CHECKED BY

DRAWN BY

THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.

10/4/2018

REV

Exhaust

Intake

Step 4:

Prebend the intake and exhaust venting, do NOT ex-

ceed 90 degrees. After the elbow, stretch the venting 

to the desired vertical height.

Step 5:

Attach the venting to the wall terminal using the sup-

plied hose clamps. Note the exhaust inlet is the inlet 

with the reducer as seen in the Figure 2. 

Step 6:

Feed the stretched venting into the exterior hole and 

down the chimney. This kit can be used from 3’-7’, trim 

any excess vent as needed. Mount the wall terminal to 

the chimney with screws. Seal as per local codes and 

regulations.

Figure 1: Cut-out size

Figure 2: Top View

Initial Installation

QUALIFIED INSTALLERS ONLY

Step 3:

Proceed to core or drill a hole at the predetermined height. Figure 1 provides dimensions for the re-

quired cut-out.

Summary of Contents for 50-3664

Page 1: ...et metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited The label plate shown on the right included with co linear venting adapter kit must be permanently attached inside the cavity of the fireplace in a visible location Note Space must be left for gas line on left side of unit for servicing purposes Install Information The flue damper must be fully block...

Page 2: ...T TH 10 4 2018 Roughly 6 3 4 Roughly 5 3 4 NOTE Holes are orientated at a 40 degree angle Roughly 5 3 Dia 4 Dia Exterior View Exhaust Intake Step 4 Prebend the intake and exhaust venting do NOT ex ceed 90 degrees After the elbow stretch the venting to the desired vertical height Step 5 Attach the venting to the wall terminal using the sup plied hose clamps Note the exhaust inlet is the inlet with ...

Page 3: ...ar of the fireplace for the Q1 C 15600 Initial Installation QUALIFIED INSTALLERS ONLY Figure 3 Venting Minimum and Maximum Step 8 Attach the venting to the top of the fireplace using 3 screws per vent Making sure the intake is on the intake collar The intake collar is on the left side of the fireplace for the Q1 and is indicated on the flue collar of the E series units by the IN Step 9 Proceed wit...

Page 4: ...us les nettoyeurs de cheminée sont bien ajustés et ne permettront pas à l air de s infiltrer dans la cheminée Les réfractaires les portes en verre les glissières les grilles et les grilles peuvent être retirés du foyer avant l installation de l appareil Installez un capuchon d évent hermétique pour empêcher toute fuite d air de la pièce par la chemi née L entrée et l échappement sont de 76 mm 3 po...

Page 5: ...BE COPIED REPRODUCED OR OTHERWISE DISCLOSED WITHOUT THE 10 4 2018 Grossièrement 6 3 4 Grossière ment 5 3 4 Remarque Les trous sont orientés à un angle de 40 degrés Grossièrement 5 3 Dia 4 Dia Vue extérieure Échappement Admission Étape 4 Prébender les entrées et sorties d air NE PAS dépasser 90 degrés Après le coude étirer la ventilation à la hauteur verticale souhaitée Étape 5 Fixez la ventilation...

Page 6: ...le Q1 et est indiqué sur le collet de cheminée des appareils de la série E par IN Étape 9 Procédez à l installation régulière pour le modèle donné La hauteur verticale minimale est mesurée à partir de la ligne centrale du collet d admission La hauteur verticale maximale est mesurée à partir de l axe du collet d échappement 5 maxi mum pour les installations Q1 Remarque le col lier d admission est p...

Reviews: