background image

29

Warranty

Sherwood  Industries  Ltd.  is  the  manufacturer  of  the  Enviro  line  of  heating  products.  At  Sherwood 

Industries, our commitment to the highest level of quality and customer service is the most important 

thing we do. Each Enviro stove is built on a tradition of using only the finest materials and is backed by 

our Exclusive Lifetime Limited Warranty to the original purchaser. With Enviro, you’re not just buying a 

stove, you’re buying a company with years of unequalled performance and quality.

Limited Lifetime Warranty:

Under this warranty, Sherwood Industries Ltd. covers the stove body and accessories against defects 

in materials and workmanship, for part repair or replacement for the first seven (7) years and limited 

labour for the first two (2) years to the original purchaser. This Warranty covers: Firebox, Stainless Steel 

Secondary  Air  Tubes,  Cabinet  Sides,  C-Cast  Ceramic  Baffle  Baffle,  Surround  Panels,  Pedestals,  Legs, 

Ceramic Glass, Slider Control and Cast Iron Door Assembly against defects. Please see the exclusions and 

limitation section below as certain restrictions and exclusions apply to this warranty. 

Limited Two (2) Year Warranty:

Under  this  warranty,  Sherwood  Industries  Ltd.  covers  all  electrical  components  against  defects  in 

materials and workmanship, for part repair or replacement for the first two (2) years and limited labour 

for the first two (2) years to the original purchaser. Please see the exclusions and limitation section below 

as certain restrictions and exclusions apply to this warranty.

Limited One (1) Year Warranty:

Under  this  warranty,  Sherwood  Industries  Ltd.  covers  all  exterior  surface  finishes  against  defects  in 

materials and workmanship, for part repair or replacement and limited labour for the first year to the 

original  purchaser.  Please  see  the  exclusions  and  limitation  section  below  as  certain  restrictions  and 

exclusions apply to this warranty.

How the Warranty Works

1. All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer 

on any oral warranty or representation. All claims under this Limited Warranty must be made in writing 

by your dealer.

2.  Any  stove  or  part  thereof  that  is  repaired  or  replaced  during  the  Limited  Warranty  period  will  be 

warranted under the terms of the Limited Warranty for a period not exceeding the remaining term of 

the original Limited Warranty or six (6) months, whichever is longer.

3.  For  any  part  or  parts  of  this  stove,  which  in  our  judgment  show  evidence  of  defects,  Sherwood 

Industries Ltd. reserves the option to repair or to replace the defective product through an accredited 

distributor or agent, provided the defective part is returned to the distributor or agent, transportation 

prepaid, if requested. Sherwood Industries Ltd. may chose to buy back the item at the cost the dealer 

was invoiced.

4. If you discover a problem that you think may be covered by the Limited Warranty, you MUST REPORT 

it to your Enviro dealer WITHIN 30 DAYS, giving them proof of purchase and the date of purchase. 

The dealer will investigate the problem and work with Sherwood Industries Ltd. to determine whether 

the problem:

a) Is covered by the Limited Warranty or 

b) Can be fixed in your home or does the product need to be returned to Sherwood Industries Ltd. 

for repair.

5. If Sherwood Industries Ltd. determines that the stove needs to be returned to Sherwood Industries 

Ltd. for repair, the customer has the responsibility and the expense of removing it from their home 

and shipping it to Sherwood Industries Ltd. If the problem is covered by the Warranty, Sherwood 

Industries Ltd. will replace the item at their discretion and the customer will be responsible for return 

shipping and re-installation in their home. 

Summary of Contents for 1200-V Insert

Page 1: ...THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your local building or fire officials or the authority having jurisdiction about restrictions and installation in...

Page 2: ...tallation 15 Removal From Pallet 15 Modifications For Installation with 191 16 484mm High Lintel 15 Masonry Fireplace Installation 16 Installation Using A Block Off Plate For USA Only 19 Model 1200 V...

Page 3: ...supplied through either the bottom or the back of the pedestal Do not burn coal or charcoal as there is danger of carbon monoxide being produced Do not use chemical fluids to start or re fresh the fir...

Page 4: ...eration the center position is off and when pushed down it will be set to automatic 3 In automatic mode set the rotary switch to the desired setting once operating temperature is reached the fan tempe...

Page 5: ...on of your stove will help to ensure safe efficient heating Please take a few moments to review these simple operating procedures IMPORTANT Please be aware when loading your stove that the air tubes i...

Page 6: ...mum fuel occurs when the stove top temperature is between 250 F 120 C and 550 F 290 C The most likely causes of dirty glass are not enough fuel to get the stove thoroughly hot burning green or wet woo...

Page 7: ...s 5 pounds 2 3 Kg of water To season firewood split and stack it so that air can get to all parts of the wood Burn beach wood only if its salt content has been washed away in a season of rain and then...

Page 8: ...e a home too airtight An easy way to stop negative pressure in a home is to crack a window in the room containing the stove b Environmental Conditions High trees low lying house location such as in a...

Page 9: ...gh Twin pilot injection ports Slider plate used for air flow control Intake air Seasoned Firewood Exhaust Smoke 1 2 Ceramic baffle reflects heat down to burn the particles in the smoke Secondary air t...

Page 10: ...t 461 8 x 28 1171 mm x 711 mm Oversized width x height 461 8 x 331 8 1171 mm x 843 mm Rating Label Location Side of Unit Behind Right Shroud 10 Specifications AIR CONTROL The air wash and pilot air co...

Page 11: ...m by non combustible spacers 14 357 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spa...

Page 12: ...by non combustible spacers 161 8 408 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible sp...

Page 13: ...1200 V INSERT 34 13 16 885mm 19 1 16 484mm or 19 9 16 497mm 22 5 16 566mm 26 15 16 684mm 20 7 8 530mm 47 3 8 1203mm 20 7 8 529mm 21 9 16 548mm 5 127mm 13 5 16 338mm 20 1 16 509mm 21 15 16 557mm Figur...

Page 14: ...700 V INSERT 34 13 16 885mm 19 1 16 484mm or 19 9 16 497mm 22 5 16 566mm 26 15 16 684mm 20 7 8 530mm 47 3 8 1203mm 20 7 8 529mm 26 1 8 663mm 5 127mm 17 7 16 453mm 24 9 16 624mm 26 1 2 672mm Figure 5 1...

Page 15: ...his is done to make unit burn more efficiently Figure 7 Rivet Figure 6 Bolts to remove 15 MODIFICATIONS FOR INSTALLATION WITH 191 16 484MM HIGH LINTEL Insert Cabinet Top Air Deflector Figure 9 Removin...

Page 16: ...ainless steel liner that goes directly to the top of the chimney and is covered with a rain cap The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner T...

Page 17: ...ure 12 Insert Installation into existing floor level masonry fireplace Installation Floor Protection Combustible Floor Masonry Fireplace 8 203 mm USA 16 406 mm CND 18 450 mm Figure 11 Insert Installat...

Page 18: ...e gasket cement When the face plate is installed onto the unit the insulation must overlaps the fireplace opening to form a seal between the masonry fireplace and the unit s face plate Let the silicon...

Page 19: ...front of the fireplace opening Refer to Step 3 NOTE In general masonry fireplaces have square fireboxes while zero clearance metal fireplaces have domed firebox tops Therefore zero clearance block of...

Page 20: ...off plate Damper must be removed Zero clearance metal firebox IMPORTANT DO NOT modify any part of the ZC fireplace 7 After installing the unit into place and the pipe through the block off plate use h...

Page 21: ...left until the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Partial Brick...

Page 22: ...the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Full Size Brick Partial B...

Page 23: ...m the plug DO NOT route the power cord beneath the heater WARNING This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a pro...

Page 24: ...e the four 4 1 2 hex head screws that hold the fan mounting plate to the shroud If doing a fan only replacement remove the four 4 T 20 screws holding the fan to the fan mounting plate 3 Remove the fan...

Page 25: ...Loosen but do not remove the four 4 1 4 screws holding the cast top 2 List the cast top off the unit and place to the side 3 Loosen the four 4 torx T 20 screws holding the face on the unit 4 Lift the...

Page 26: ...standards Install and use only in accordance with the manufacturers installation and operating instructions Contact local building or fire officials about restrictions and installation inspection in...

Page 27: ...50 1105 16 Glass Retainer Kit With Screws 50 1122 17 1200 1700 Left Shield Assembly 50 1144 18 1200 1700 Right Shield Assembly 50 1145 19 1200 C Cast Ceramic Baffle 1 Piece 50 1146 20 1700 C Cast Cera...

Page 28: ...28 Parts Diagram 10 11 13 12 4 25 5 3 2 1 17 7 18 23 21 29 26 22 6 32 33 16 31 34 28 30 27 8 19 20 9 9 14 15 24...

Page 29: ...l purchaser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set her...

Page 30: ...ty will cover glass thermal breakage only and will not cover misuse of the stove glass including but not limited to a Glass that is struck has surface contaminates or has had harsh or abrasive cleaner...

Page 31: ...esentations 24 Sherwood Industries Ltd will not cover the cost of the removal or re installation of the stove hearth facing mantels venting or other components 25 Labour to replace or repair items und...

Page 32: ..._________________ _________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHA...

Reviews: