background image

Page 6

economical. safe. simple.

HOW IT WORKS

The Envi Heater is designed with innovative “Stack Convection Technology” that eff ectively heats a room with minimal energy.  
The Envi’s inner chamber simulates “stacks” of varying height, which boost airfl ow through the heater to achieve maximum 
effi  ciency. The end result is enhanced airfl ow at safe air temperature, all without the use of a fan. The Envi heater will provide 
consistent, comfortable, silent heat without drying out the air or leaving cold spots in the room.

OVERHEAT SAFETY FEATURE

This heater is equipped with an overheat safety feature. When the heaters internal components reach a certain temperature 
that could cause overheating and a possible fi re, the heater will automatically shut off . To reset the heater, unplug the heater 
power cord from the electrical outlet for 10 minutes. After 10 minutes, plug the heater into the electrical outlet and turn on us-
ing the heater’s on/off  switch located on the front of the unit.

WALL-SENS

TM

 SAFETY FEATURE

In addition to the overheat safety cut-off , the Envi Heater is now equipped with an additional layer of safety to give you greater 
peace of mind.  Wall-Sens

TM

 technology means that in the event that the Envi heater is ever removed from the wall, power will 

be immediately cut to the heater.  This of course means that the heater will not work if it is simply removed from its packaging 
and plugged into a wall outlet.  It must be mounted properly (safely) and then plugged in (or hardwired) in order for it to be 
begin to heat.  

GROUNDING

Plug-in models of the envi heater are for use on standard electrical circuits (eg. 120v for USA/Canada). The cord has a three-
blade grounding plug. An adapter can be obtained at most hardware or electrical stores for connecting three-blade grounding 
type plugs to two-slot receptacles. The grounding lug extending from the adapter must be connected to a permanent ground 
such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.  

DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG.

OPERATING INSTRUCTIONS

1.  Install the heater on a fi rm, level wall and plug the power cord 

into a grounded power outlet (or hardwire it if applicable). The 
heater will only operate when it is properly attached to the 
mounting clips. Be sure to mount in upright position with the 
thermostat knob on the top of the heater.

2.  Once the heater is connected, press the front on/off  power 

switch and the POWER INDICATION LIGHT will glow red. (Fig. 5)

3.  The Envi Heater is equipped with a built-in thermostat which is 

adjusted with a dial at the top of the heater.  Adjust the room 
temperature by turning the THERMOSTAT DIAL clockwise to 
increase the room temperature. If the area becomes too warm, 
rotate the THERMOSTAT DIAL counter-clockwise until you reach a point where the temperature is more comfortable. (Fig. 5)

4.  Once you have chosen the desired setting, the thermostat will maintain a constant temperature.  NOTE:  Models with no 

thermostat have no temperature control and will stay on until the heater is powered off .

5.  The heater is equipped with an innovative auto dimming feature that dims the power indication light for light sleeper in 

darkened bedrooms. The heater automatically 
detects when the light level in a room drops and then dims the power light.

6.  The plug-in cordset of the Envi heater can be stored inside the bottom access door.  Determine how much cordset you 

require to extend out of the heater.  Remove the heater from the wall, and remove the bottom access door.  Carefully push 
the excess cordset inside the heater and replace the bottom access door.  Re-install the heater to the wall and plug-in the 
cordset to continue using your heater.  For more information please visit the installation web page of www.eheat.com

OPTIMAL OPERATING CONDITIONS

To get the most out of your Envi Heater, please follow these helpful hints:

1.  VERY IMPORTANT!!! For optimal performance in a room, close all windows and doors and for fi rst time use, leave on 

for 48 - 72 hrs. 

This will allow the room to reach equilibrium temperature while the heat is gradually building up. 

2.  For optimal performance, mount the heater on an interior wall with the bottom of the heater 6” to 8” (15 to 20cm) from the 

fl oor. For smaller rooms this can be increased with little detriment, however try to keep the bottom of the heater a maxi-
mum of 18” (46cm) from the fl oor.

3.  The 475 Watt Envi heater is designed to heat rooms 130 to 150 ft

2

 feet in size (12m

2

 to14m

2

).  This equates to a 10ft x 14ft 

room size (3 x 4meters). Of course, this will vary depending on a number of factor, including outdoor temperature, room 

OPERATING INSTRUCTIONS

Summary of Contents for HH1012T

Page 1: ...Certifications p 7 Warranty p 8 MODELS COVERED BY THIS MANUAL 475 Watt 120 Volt Models HH1012T Plug In with Thermostat HH1012N Plug In No Thermostat HW1012T Hardwired with Thermostat HW1012N Hardwire...

Page 2: ...to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before installing or using this heater 2 Extreme caution is necessary when any heater i...

Page 3: ...o anchor locations and secure firmly to the wall anchors using the provided screws see Fig 3 DO NOT overtighten There should be a gap behind the mounting clip to hang the heater on 4 If you plan on us...

Page 4: ...Install heater on mounting clips align right side first and make sure to press down firmly on the heater to ensure a secure fit You will hear it snap into place Fig 5 above 6 OPTIONAL Install the thir...

Page 5: ...a screw driver can be used on the back of the heater and install the supplied protection grommet into the knockout hole The bottom access door is already removed and supplied in the mounting kit Pull...

Page 6: ...rly attached to the mounting clips Be sure to mount in upright position with the thermostat knob on the top of the heater 2 Once the heater is connected press the front on off power switch and the POW...

Page 7: ...position PRODUCT SPECIFICATIONS SAFETY LISTINGS COMMERCIAL FIRE SAFETY COMPLIANCE CALIFORNIA TITLE 24 CERTIFICATION insulation room draftiness room objects etc 4 To save energy and to reduce your heat...

Page 8: ...er than those authorized by the Manufacturer Freight and Insurance cost for the warranty service 4 ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO A THREE YEAR DURA TI...

Reviews: