![Envertech EVT360 User Manual Download Page 5](http://html1.mh-extra.com/html/envertech/evt360/evt360_user-manual_2415544005.webp)
3.3 Datasheet
4.Packing checklist
After you receive the Envertech microinverter, please check if there is any damage on the carton,
and then check the inside completeness for any visible external damage on the microinverter and
accessories. Contact your dealer if anything is damaged or missing.
5
6
5.Planning of Microinverter Installation
4.1 Accessories
4.2 Product Description
If you have any further questions concerning accessories or installation, please check our website
www.envertec.com or send an email to [email protected].
4.3 Further information
Item
Description
A
B
C
D
E
DC connectors
AC connector
LED light
Wall bracket hole
Grounding hole
An error has occurred
Please go to Chapter 10 “Trouble Shooting” to repair the error.
This device SHALL NOT be disposed of in residential wastePlease go to
Chapter 9 “Recycling and Disposal” for proper treatments.
No unauthorized perforations or modifications
Any unauthorized perforations or modifications are strictly forbidden. If any
defect or damage (device/person) is occurred, Envertech shall not take any
responsibility for it.
Symbol
Description
Dangerous electrical voltage
This device is directly connected to public grid, thus all work related to
theinverter shall only be carried out by qualified personnel.
NOTICE, danger!
This device directly connected with electricity generators and public grid.
Danger of hot surface
The components inside the inverter will release a log of heat during
operation. DO NOT touch aluminum casing during operating.
Model
Input Data (DC)
Recommended input power range (W)
Max. DC input (Vdc)
Isc PV (absolute Max.) (A)
Operating range (Vdc)
Max. input current (A)
Mppt Voltage range (Vdc)
180W~450W+
60V
15A
16V-60V
12A
22~48V
Normal Voltage (Vac)
Frequency (Hz)
Current (Max. continuous) (A)
Power (Max. continuous) (W)
Power factor range
Total Harmonic Distortion
Maximum units per branch
Peak inverter efficiency
EURO weighted efficiency
MPPT efficiency
Nighttime power consumption
Ingress protection (IP)
Protective class
Temperature(℃)
Relative humidity
Overvoltage category
Inverter Isolation
Weight
Dimensions
95.6%
95%
99.9%
<100 mW
IP 67
Class I
-40℃ to +65℃
0%~98%
OVC III (AC Main), OVC II ( PV)
High Frequency Isolated
1.8kg
163 mm x 216 mm x 27 mm
220V/230V
50Hz/60Hz
1.63A
360 W
+/-0.90
<3%
16 Units (12AWG Cable)
Communication
Compliance
Warranty
PLCC(Power Line Carrier Communication)
VDE-AR-N 4105, IEC/EN61000, IEC/EN62109-1/2,
EN50549-1/2019, TOR 2019, C10/11:2019,
UTE C15-712-1:2013, VFR 2019
15 Years
Output Data (AC)
Efficiency
Features
Others
EVT360
5.1
Symbols on Inverter
D
C
B
A
E