1.1 Read it First

This manual contains important instructions for installation and maintenance of the 
EVT360 microinverter. 
To reduce the risk of electrical shock, and to ensure safe installation and operation of 
the microinverter, the following safety symbols appear throughout this document to 
indicate dangerous conditions and important safety instructions.

The Envertech microinverter system is an on-grid microinverter system with world 
top-class technology. This manual gave details about safe installation and operation 
of the Envertech Microinverter. 
The three key elements of an Envertech microinverter system include : 

Do not use Envertech equipment in a manner not specified by the manufacturer. Doing so may cause 
death or injury to persons, or damage to equipment. 
Be aware that only qualified personnel should install or replace the Envertech microinverters and the 
Cable and accessories. 
Do not attempt to repair the Envertech microinverter; it contains no user-serviceable parts. If it fails, 
contact Envertech customer service to start the replacement process. Tampering with or opening the 
Envertech microinverter will void the warranty. 
If the AC cable on the microinverter is damaged or broken, do not install the unit. 
Before installing or using the Envertech microinverter, read all instructions and cautionary markings 
in the technical description and on the Envertech microinverter system and the PV equipment. 

Connect the Envertech microinverter to the utility grid only after you have completed all installation 
procedures and receiving approval from the electric utility company.  
Please be kindly noted that the Envertech microinverter itself is a heat sink. Under normal operating 
conditions, its temperature is 20°C above ambient, but under extreme conditions the microinverter 
can reach a temperature of 80°C.

Do not disconnect the PV module from the Envertech microinverter without firstly disconnecting AC 
power. 

2. Envertech Microinverter System

1.2 Safety Instructions

1

2

!

WARNING

DANGER

DANGER indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

WARNING indicates a hazardous situation which, if not avoided, 
can result in death or serious injury or moderate injury.

NOTICE indicates a situation that can result in property damage,
 if not avoided.

!

NOTICE

!

1.Important Safety Information

EnverBridge: monitoring and protecting PV system.

EVT360 microinverter:Converting the DC of the PV module into AC

EnverPortal: http://www.envertecportal.com

Summary of Contents for EVT360

Page 1: ...60 MICROINVERTER User Manual Zhejiang Envertech Corporation Ltd Tel 86 579 8926 6326 Web www envertec com Email info envertec com Add 24th Floor Jintong Mansion Center of Headquarters Yongkang City Zh...

Page 2: ...cription 4 3 Further information 5 Planning of Microinverter Installation 5 1 Symbols on Inverter 5 2 Accessories 5 3 Connection Method 6 Microinverter Installation 7 Debugging and Operaing 7 1 Energi...

Page 3: ...f the AC cable on the microinverter is damaged or broken do not install the unit Before installing or using the Envertech microinverter read all instructions and cautionary markings in the technical d...

Page 4: ...Faulty grounding protection Grid monitoring Current monitoring in grounding DC current monitoring EVT360 can be adapted to almost all 60 cell or 72 cell modules Before installation please check the pa...

Page 5: ...to public grid thus all work related to theinverter shall only be carried out by qualified personnel NOTICE danger This device directly connected with electricity generators and public grid Danger of...

Page 6: ...allation could only be implemented when the system is discon nected from the grid and the solar panel has been covered or discon nected WARNING 1 Mount microinverters onto the rack Mark out the estima...

Page 7: ...EVB300 plug into the socket Option 2 Wireless mode 1 Fix EVB300 at proper position in or close to the distribution box within the range Wi Fi signal 2 Turn off the air switch and connect EVB300 s powe...

Page 8: ...al com Click Sign Up Fill in the account information to finish registration Step 2 Under Device Management click Add and enter MI SN manually or click the QR Code icon on the right to scan the MI SN a...

Page 9: ...to manage grid parameters after all microinverters have been detected 7 2 EVT360 Operation The Envertech microinverter is powered on when there is sufficient DC voltage from the PV module The LED lig...

Page 10: ...f the load centers are within the ranges shown in the following table 4 Verify that AC line voltage at the junction box for each AC branch circuit is within the ranges required by local grid standards...

Page 11: ...reached its lifetime must be collected separately to the unit or individual that has obtained the qualification for disposing discarded electrical and electronic products For any equipment that you n...

Reviews: