The DMX port

  represents one of the physical ports on

the rear of this unit, select which port you want to use by
using the drop down.

Rate:   refresh   rate   to   send   DMX   (frames   per
second)

Break: Break time (micro sec) between each DMX
frame (default is 200)

MAB: Mark After Break time (micro sec) default is
52

Channels:   Number   of   channels   to   send   in   1
Universe (default is 512)

Limitation

: Same DMX port cannot be re-used in the same

profile

Art-Net Stream:

 "Send IP address": is the destination

address used when the stream is sending data only.

ESP   Stream

:   ENTTEC   Show   protocol   DMX   over

Ethernet   stream   (ESP).   IP   address   is   the   destination
address used when the stream is sending data only.

Kinet Stream

:  For example:  You can connect  Kinet

Stream to an Art-Net Stream to convert and output as
Art-Net. (Kinet stream is supported as input only)

Streaming ACN

: "IP address" is the destination address

used   when   the   stream   is   sending   data   only 
(default is disabled = 0.0.0.0)

DMX Generator

: Define your own custom DMX Channel

values and assign the selected ones. 

Snapshot feature can be used to capture values from an
input   stream.   All  modifications   can  be   done   using   the
DMX  Grid Page.

Clock:  

Allows   you   to   synchronize   ALL  DMX   output   only

when the connected Input Stream is received.

Auto-repeat allows user to repeat the output once
every   "number   of   seconds"   reagrdless   of   Synced
Stream

Default behaviour [Auto-repeat = Never]: Will only
refresh DMX when Synced Stream is received

The Clock module can be used to make sure the output is
always   synced   to   the   “latest   universe”   -   especially   if   the
source   adds   a   delay   to   each   univere.   This   will   keep   all
outputs in sync with the latest one.

5

Summary of Contents for STORM 24

Page 1: ...ating and editing ports is flow chart oriented and documents data flow as you configure it Number of channels configurable for each DMX port 1 to 512 Supports following DMX over Ethernet protocols ESP...

Page 2: ...ion for some or all of the following DMX Ports These are the physical OUTPUT DMX ports 1 24 Ethernet Streams These are the DMX over Ethernet universes Art Net ESP KiNET ACN Routing Diagram The routing...

Page 3: ...eed a license to activate 2 Setup 1 Change IP 2 Factory Reset Setup screen allows changing the IP address of the unit via Change IP or doing Factory Reset Change IP This screen further gives two optio...

Page 4: ...con Web Profiles From this screen you can manage your profiles As you will notice in the Remarks column the factory default profiles are read only If you wish to modify one of them you will first need...

Page 5: ...For example You can connect Kinet Stream to an Art Net Stream to convert and output as Art Net Kinet stream is supported as input only Streaming ACN IP address is the destination address used when th...

Page 6: ...p you find your unit s IP address and then open a browser window to make the required changes To employ the NMU follow this set of instructions 1 If you have not already done so download and proceed t...

Page 7: ...using the following part numbers ENTTEC PTY LTD ENTTEC AMERICAS 17 5 Samantha Court 604A Cornerstone Ct Knoxfield Victoria 3180 Hillsborough NC 27278 Australia USA Tel 61 3 9763 5755 Tel Fax 888 454...

Reviews: