background image

DIN ETHERGATE (71030) 

Visit the ENTTEC website for the latest version. 

.. 

 

USER MANUAL  

8

 |

 

ID: 5928465 

Document Updated: August 2022 

 

  

 

value is set on the output. 

 

 

LTP Merge

: Latest Takes Precedence. The latest source received is used as the output.

 

Hardware features 

 

Forward facing LED status indicator. 

 

 

Electrically insulated ABS plastic housing.

 

 

Surface mount or TS35 DIN mount (using included DIN Clip accessory).

 

 

Two bi-directional DMX ports.

 

 

Inbuilt DMX termination.

 

 

IEEE 802.3af PoE (active PoE).

 

 

Link & Activity LED indicator built into RJ45 port.

 

 

2 Pin DC power input phoenix 12->24v.

 

 

Pluggable terminal blocks.

 

Phoenix Pinout 

The  DIN  ETHERGATE  features  two  4  Pin  Phoenix 

Connectors, which can be used either for DMX in or DMX 

out,  depending  on  the  settings  set  within  the  Web 

Interface. 

 

The Phoenix connectors feature the DMX standard ports 

(0V, Data - and Data +), with an additional port called 

Term which is used when the DIN ETHERGATE is being 

used as a DMX to eDMX converter. The TERM  port will 

replace the need for the Data + port and will provide 

termination to your DMX line.

 

PoE (Power over Ethernet) 

The DIN ETHERGATE supports IEEE 802.3af Power over Ethernet. This allows the device to be powered via 

the RJ45 EtherCon Connection, reducing the number of cables and the ability to remotely deploy the DIN 

ETHERGATE without the need for a local power source close to the device.

 

PoE can be introduced to the Ethernet cable, either through a network switch which outputs PoE under the 

IEEE 802.3af standard, or through an IEEE 802.3af PoE injector.

 

Note:

 DC power input has higher priority over PoE. In the event of DC power input disconnection, please 

expect approximately 1 minute down time before DIN ETHERGATE reboots for PoE to take over. 

 

Note:

 Passive PoE is not compatible with the DIN ETHERGATE.

 

 LED Status Indicator 

The DIN ETHERGATE comes with a forward facing RGB LED indicator. The LED signifies the related activity:

 

LED Color 

DIN ETHERGATE 

Status 

Description 

White (static) 

Idle

 

This signifies that the DIN ETHERGATE is operating normally.

 

Green 

DMX input or 

output on Port 1 

 

The LED will fade from white to green. Please disable Port1 if you 

don't want it to function.

 

Summary of Contents for 71030

Page 1: ...y computer on your network The DIN ETHERGATE s slim 4 DIN module electrically insulated housing supports TS35 DIN and surface mounting for fast installation Pluggable terminal blocks with inbuilt term...

Page 2: ...delines 4 Physical Dimensions 4 Wiring Diagrams 5 Mounting Options 6 Functional features 7 Bi directional eDMX Protocols and USITT DMX512 A Conversion 7 Merging 7 Hardware features 8 Phoenix Pinout 8...

Page 3: ...mpatible Remove power from your installation immediately if accessories power cables or connectors is in any way damaged defective shows signs of overheating or are wet Provide a means of locking out...

Page 4: ...suitable personal protective equipment when installing ENTTEC products Once installation is completed check that all hardware and components are securely in place and fastened to supporting structure...

Page 5: ...w terminals The DIN ETHERGATE s RJ45 network connector accepts cabling terminated to the TIA EIA networking standard Network cabling should be terminated with an RJ45 connector in accordance with the...

Page 6: ...DIN ETHERGATE 71030 Visit the ENTTEC website for the latest version USER MANUAL 6 ID 5928465 Document Updated August 2022 Mounting Options...

Page 7: ...3999 sACN priority of the output can be defined default priority 100 The DIN ETHERGATE supports a maximum of 1 multicast universe with sACN sync i e both universe outputs set to the same universe ESP...

Page 8: ...place the need for the Data port and will provide termination to your DMX line PoE Power over Ethernet The DIN ETHERGATE supports IEEE 802 3af Power over Ethernet This allows the device to be powered...

Page 9: ...is slow to respond or your network does not have a DHCP server the DIN ETHERGATE will fall back to the Static IP address If a DHCP address is provided this can be used to communicate with the DIN ETHE...

Page 10: ...opting to configure the device Note The eDMX protocols the controller and the device using to configure the DIN ETHERGATE must be on the same Local Area Network LAN and be within the same IP address...

Page 11: ...ocol RDM RDM ANSI E1 20 can be Enabled using the tick box This is only available when the Type is set to Output and the Protocol is Art Net More information can be found in the Functional Features sec...

Page 12: ...ets last IP address and Port Art Net Statistics also provide a breakdown of Art Net DMX packets sent and received As well as a breakdown of RDM over Art Net packets including packet sent and received...

Page 13: ...eaned in a schedule fit for the environment it is installed within to ensure maximum product longevity Cleaning schedules will vary greatly depending on the operating environment Generally the more ex...

Page 14: ...luded Revision History Firmware version V2 0 and 12V 24V DC input voltage range implemented from Serial Number 2361126 onwards July 2022 Please check your serial number and artwork on your device Orde...