DIN ETHERGATE (71030) 

Visit the ENTTEC website for the latest version. 

.. 

 

USER MANUAL  

10

 |

 

ID: 5928465 

Document Updated: August 2022 

 

  

 

address can be typed directly into the web browsers URL field. 

 

Unidentified IP address:

 If you are not aware of the DIN ETHERGATE’s IP address (either DHCP or Static) the 

following discovery methods can be used on a local network to discover devices:

 

 

An IP scanning software application (i.e. Angry IP Scanner) can be run on the local network to return a 

list of active devices on a local network.

 

 

Devices can be discovered using Art Poll (i.e. DMX Workshop if set to use ArtNet).

 

 

The device Default IP address 192.168.0.10 is printed on the physical label on the rear of the product.

 

 

ENTTEC EMU software (available for Windows and MacOS), which will Discover ENTTEC devices on the 

Local  Area  Network,  will  display  their  IP  addresses  and  open  to  the  Web  Interface  before  opting  to 

configure the device.

 

Note:

 The eDMX protocols, the controller and the device using to configure the DIN ETHERGATE must be on 

the same Local Area Network (LAN) and be within the same IP address range as the DIN ETHERGATE. For 

example, if your DIN ETHERGATE is on Static IP address 192.168.0.10 (Default), then your computer should be 

set to something such as 192.168.0.20. It is also recommended that all devices Subnet Mask are the same 

across your network. 

 

Home 

The landing page for the DIN ETHERGATE web interface is the Home tab. This tab is designed to give you a 

read-only device overview. This will display: 

 

System Information:

 

 

Node Name

 

 

Firmware Version

 

Current Network Settings: 

 

 

DHCP Status

 

 

IP Address

 

 

NetMask

 

 

Mac Address

 

 

Gateway Address

 

 

sACN CID

 

 

Link Speed

 

Current Port Settings:

 

 

Port 

 

 

Type 

 

 

Protocol

 

 

Universe

 

 

Send Rate

 

 

Merging

 

 

Send to Destination

 

Current DMX Buffer:

 The Current DMX buffer displays a snapshot of all current DMX values when refreshed 

manually.

 

Settings 

The DIN ETHERGATE settings can be configured within the Settings tab. Changes will only take affect after 

Summary of Contents for 71030

Page 1: ...y computer on your network The DIN ETHERGATE s slim 4 DIN module electrically insulated housing supports TS35 DIN and surface mounting for fast installation Pluggable terminal blocks with inbuilt term...

Page 2: ...delines 4 Physical Dimensions 4 Wiring Diagrams 5 Mounting Options 6 Functional features 7 Bi directional eDMX Protocols and USITT DMX512 A Conversion 7 Merging 7 Hardware features 8 Phoenix Pinout 8...

Page 3: ...mpatible Remove power from your installation immediately if accessories power cables or connectors is in any way damaged defective shows signs of overheating or are wet Provide a means of locking out...

Page 4: ...suitable personal protective equipment when installing ENTTEC products Once installation is completed check that all hardware and components are securely in place and fastened to supporting structure...

Page 5: ...w terminals The DIN ETHERGATE s RJ45 network connector accepts cabling terminated to the TIA EIA networking standard Network cabling should be terminated with an RJ45 connector in accordance with the...

Page 6: ...DIN ETHERGATE 71030 Visit the ENTTEC website for the latest version USER MANUAL 6 ID 5928465 Document Updated August 2022 Mounting Options...

Page 7: ...3999 sACN priority of the output can be defined default priority 100 The DIN ETHERGATE supports a maximum of 1 multicast universe with sACN sync i e both universe outputs set to the same universe ESP...

Page 8: ...place the need for the Data port and will provide termination to your DMX line PoE Power over Ethernet The DIN ETHERGATE supports IEEE 802 3af Power over Ethernet This allows the device to be powered...

Page 9: ...is slow to respond or your network does not have a DHCP server the DIN ETHERGATE will fall back to the Static IP address If a DHCP address is provided this can be used to communicate with the DIN ETHE...

Page 10: ...opting to configure the device Note The eDMX protocols the controller and the device using to configure the DIN ETHERGATE must be on the same Local Area Network LAN and be within the same IP address...

Page 11: ...ocol RDM RDM ANSI E1 20 can be Enabled using the tick box This is only available when the Type is set to Output and the Protocol is Art Net More information can be found in the Functional Features sec...

Page 12: ...ets last IP address and Port Art Net Statistics also provide a breakdown of Art Net DMX packets sent and received As well as a breakdown of RDM over Art Net packets including packet sent and received...

Page 13: ...eaned in a schedule fit for the environment it is installed within to ensure maximum product longevity Cleaning schedules will vary greatly depending on the operating environment Generally the more ex...

Page 14: ...luded Revision History Firmware version V2 0 and 12V 24V DC input voltage range implemented from Serial Number 2361126 onwards July 2022 Please check your serial number and artwork on your device Orde...