Model: EP.MINI
ENTRY
PASS
Advisable to
perform format
memory for the
first time you turn
on the power
To configure the
EP.MINI unit address
if there is more than
1 MINI controller
connected to the PC
communicator
MINI (10 digit firmware) Programming Mode
Exit Button Tz
•Enter programming mode
•01 Enter
•02 Enter
•09 Enter
•Key in the new exit button timezone
•ESC X3
Auto Release Tz
•Enter programming mode
•01 Enter
•02 Enter
•10 Enter
•Key in the new auto release timezone
•ESC X3
Release Time
•Enter programming mode
•01 Enter
•02 Enter
•11 Enter
•Key in the new release time (00 – 99)
•ESC X3
Open Time
•Enter programming mode
•01 Enter
•02 Enter
•12 Enter
•Key in the new open time (00 – 99)
•ESC X3
Pin Trials
•Enter programming mode
•01 Enter
•02 Enter
•13 Enter
•Key in the new pin trials (00 – 09)
•ESC X3
Card+Pin Tz
•Enter programming mode
•01 Enter
•02 Enter
•14 Enter
•Key in the new card+pin timezone
•ESC X3
Date Setting
•Enter programming mode
•01 Enter
•03 Enter
•Key in the new date (DDMMYY)
•ESC X2
Time Setting
•Enter programming mode
•01 Enter
•04 Enter
•Key in the new time (HHMMSS)
•ESC X2
Reset Password
•Enter programming mode
•01 Enter
•05 Enter
•01 Enter
•ESC X2
Reset Door Data
•Enter programming mode
•01 Enter
•05 Enter
•02 Enter
•ESC X2
Format Memory
•Enter programming mode
•01 Enter
•05 Enter
•03 Enter
•When finish formatting, a beep sound will be heard
•ESC X2
Install Card
•Enter programming mode
•02 Enter
•01 Enter
•01 Enter
•Key in the card number (10 digits)
•ESC X3
Delete Card
•Enter programming mode
•02 Enter
•01 Enter
•02 Enter
•Key in the card number (10 digits)
•ESC X3
View Card
•Enter programming mode
•02 Enter
•01 Enter
•03 Enter
•Key in the card number (10 digits)
•ESC X4
Quick Install
•Enter programming mode
•02 Enter
•01 Enter
•04 Enter
•Flash all the cards to be installed (card by card)
•ESC X4
25