Model: EP.MINI
Connecting the Exit Reader – MINI reader as an exit reader
ENTRY
PASS
To use MINI/NMINI on exit reader side, you must enable the READER MODE function on the
programming mode
To configure
MINI
as a
READER Mode, press:
•
F1
•
123456
•
01 Enter
•
01 Enter
•
05 Enter
•
1 Enter
•
ESC x3
To configure
NMINI
as a
READER Mode, press:
•
F1
•
123456
•
01 Enter
•
01 Enter
•
04 Enter
•
1 Enter
•
ESC x3
0 V
+12 VDC
Exit Reader
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Green (D0)
White (D1)
Black (Gnd)
Red (+12VDC)
Black (Gnd)
Red (+12VDC)
Orange (RCLK)
Yellow (RDAT)
13