Display
Description
Selections
available
CA - Setting the maintenance alarm
(factory setting - alarm deactivated: 0.0 00. 00).
You can set the required number of operations (regarding the partial operations counter)
for signalling the maintenance alarm.
When the set number of operations is reached, the alarm message appears on the
display
.
Example:
Setting the maintenance alarm after 700 operations (00) (07) (00)
→
→
→
→
→
→
→
→
→
2”
OA - Selecting maintenance alarm display mode
00 - Visualisation on display (alarm message
)
01 - Visualisation on flashing light (with the automation idle, 4 flashes are
made and then repeated every hour) and on display (alarm message
).
02 - Visualisation on "open gate" indicator light (with the automation closed,
4 flashes are made and then repeated every hour) and on display (alarm
message
).
ZP - Reset of partial operations counter
→
2”
For correct functioning, you are advised to reset the partial operations counter:
- after maintenance work;
- after setting the maintenance alarm interval.
11.7.1 Additional CC level parameters that can be configured
(available with
→
enabled)
11.8 Second level menu - EM (Energy Management)
Display
Description
Selections
available
PV - Solar panel power supply (panels not supplied)
ON - Enabled
OF - Disabled
LB - Indication that batteries are almost flat
00 - Visualisation on display (alarm message
)
01 - Visualisation on flashing light (with the automation idle, 2 flashes are
made and then repeated every hour) and on display (alarm message
)
02 - Visualisation on "open gate" indicator light (with the automation closed, 2
flashes are made and then repeated every hour) and on display
(alarm message
)