Failed internal BUS communi-
cation.
Check the control panel is working properly.
No Master/Slave presence
with automations in simulta-
neous synchronism.
Check the correct power supply is reaching the au-
tomations.
Factory initialisation incom-
plete.
Contact Technical Support.
Operation time-out error.
If the alarm persists, contact Technical Support.
Motor drive fault.
If the alarm persists, contact Technical Support.
Motor current fault.
If the alarm persists, contact Technical Support.
Me
ch
an
ic
al
al
ar
m
Automation blocked.
Check the blocking device is working properly.
Check there are no obstacles near the end stops.
Motor short circuit.
Check the motor is correctly connected.
Check the motor is working properly.
Me
ch
an
ic
al
al
ar
m
Absence of motor during an
operation.
Check the motor is correctly connected.
Irregular operation of the
opening limit switch.
Check correct connection of the opening limit
switch.
Irregular operation of the clos-
ing limit switch.
Check correct connection of the closing limit
switch.
Detection of the third
consecutive obstacle.
Check for the presence of permanent obstacles
along the stroke of the automation.
Powe
r s
up
pl
y
al
ar
m
No power supply.
Check the control panel is powered correctly.
Mains voltage too low.
Check the automation power supply voltage.