9. Working modes for sliding gates
The control panel can work in the following 3 modes:
• automations with encoder (DIP5B=ON) and without stop limit switches,
the automation stops on the mechanical stops;
• automations with encoder (DIP5B=ON) and with stop limit switches,
the automation stops after the stop limit switches have tripped;
• automations without encoder (DIP5B=OFF) and with stop limit switches,
the automation stops after the stop limit switches have tripped.
In the automations with encoder (DIP5B=ON), by selecting DIP6B=ON, the control panel activates an innovative automatic detection
system for the current necessary to move the automation at any point of the opening and closing operation.
The current stored profile shows the forces necessary for correct movement, taking the frictions into consideration.
The current profile is automatically updated every time an operation is completed (opening-closing) and it gradually adapts to the
frictions resulting from progressive and natural ageing of the gate frame, reducing the need to service.
N.B.: The current profile is kept stored even in the event of a power failure.
WARNING
The operations related to point 6 are performed without safeties.
The trimmer can only be adjusted with the automation idle.
The automation automatically slows when approaching the end stops or stop limit switches.
After start-up the control panel receives a RESET and the first operation is performed at
reduced speed (automation position acquisition).
10. Start-up
10.1 Starting the sliding gates
1-
Make a jumper for NC safety contacts.
2-
Check that the storage module corresponding to the type of application selected is correctly plugged in.
3-
Adjust the opening and closing stop limit switches, if any.
N.B.: limit switches must be kept pressed until the operation has been completed.
4-
Set TC=MAX and R1=50%.
Select the desired opening direction with DIP2A.
Set DIP4B=OFF and DIP6B=OFF.
5-
Manually move the sliding gate and make sure the entire stroke slides evenly and without friction.
6-
Switch on and check the automation is operating correctly with the subsequent opening and closing commands.
Check that the limit switches are activated if used.
7-
Connect the safety devices (removing the relative jumpers) and check they function correctly.
8-
If desired, adjust the automatic closing time with the TC trimmer.
WARNING: the automatic closing time after a safety device has triggered depends on the DIP3A setting.
9-
Set the desired opening and closing speed with the VA and VC trimmers.
10- Connect any other accessories and check they are functioning.
11- Set the obstacle thrust with the R1 trimmer.
To enable the current profile (see chapter 9) proceed as indicated:
• set DIP6B=ON (any previously stored current profile is reset);
• perform 2 complete operations (opening-closing).
12- For correct operating of the sliding gate with the correct operating forces, we recommend using the following settings:
• gate without rubber edges: DIP4B=ON and DIP7B=ON;
• gate with rubber edges: DIP4B=ON and DIP7B=OFF;
• gate with self-controlled safety edges: DIP4B=OFF and DIP7B=OFF.
WARNING: After adjusting, check that the working forces exerted by the door wings comply with standards EN12453-EN12445.