29
IP2253EN - 2017-08-21
6.1 Preliminary checks
6. Installation
The declared operating and performance features can only be guaranteed with the use of EN-
TREMATIC accessories and safety devices.
Unless otherwise specified, all measurements are expressed in mm.
Make sure the gate structure is sturdy and the hinges are lubricated and smooth.
If possible, fit an opening and closing stop. Otherwise, use the built-in mechanical stops and/or
the electric limit switches (optional) if available. The mechanical construction elements must
comply with the requisites of Standard EN12604.
The installation measurements indicated in the table allow you to choose the values of [A] and [B] on
the basis of the required opening angle and in relation to the on-site spaces and overall dimensions.
Increasing measurement [A], you reduce the opening approach speed.
Reducing measurement [B], you increase the gate opening angle.
Measurements [A] and [B] must, however, be compatible with the effective piston stroke.
A
P
D
E
L
B
C
min 60 con apertura a 90°
S
i
The automation fastening point varies according to the space available and the gate to be
automated. The installer must therefore choose the best solution to ensure that the system
works correctly in each individual situation.
min 60 with 90° opening
Tab. 6.1
A
B
C
S
D
E
L
P min
200
190
20
170
120°
120
910
220
200
200
50
150
110°
220
100
220
50
170
90°
120
130
210
70
140
95°
150
170
220
100
120
95°
190
200
190
100
90
100°
220
150
220
150
70
95°
170
130
290
220
70
90°
150