Figure 37: Not Initialized Unit Warning
NOTE: Any time the “Not Initialized Unit Warning” appears on the LCD display, the unit needs a Doors update.
Figure 38: EntraGuard Gold Default LCD Display
NOTE: The default display will remain until a message banner has been created (for instructions on how to create a
message banner see the Doors Users Guide - P/N 01821-002).
8.1.1
The Master Controller
1
The Master Controller must be set to address 1 so that all slave controllers on the access control network can identify
the master controller. For the Master Controller to correctly identify all slave controllers on the network, one of two
things must be done.
1. The master controller must be the last unit on the network to be powered on. This ensures that when the Master
Controller begins polling the network to see what slave units are connected for system configuration, all slave units
are ready to communicate their unique addresses and their configuration information.
2. The Auto-Configuration routine within the
Doors
program must be run. This instructs the Master Controller to poll
all controllers on the network for addresses and configuration information.
NOTE: An auto-configuration must be performed any time changes are made to the 485 network.
1. The EntraGuard Gold Controller must be installed as the Master Controller in a mixed EntraGuard/PXL
network.