Set Unit Address
The controller’s address may only be set through the Reset Menu. Once you have performed the necessary steps to
reach the Reset Menu as described above, if the EntraGuard Gold unit has an alpha/numeric keypad, the keypad will
default to the numeric keypad (if the alpha keypad is lit instead, press the #/A key to return to numeric mode). To set the
desired operating address for the controller, press 1 on the keypad. The Set Panel Address screen appears on the LCD
(see Figure 35).
Figure 35: Set Unit Address
The address range is from 1 to 128. On a mixed EntraGuard/PXL network, the EntraGuard unit must be set as the
Master Controller and the Master Controller must be set to address 1. Other slave EntraGuard/PXL-250 controllers may
be assigned any number from 2 to 128.
If the address shown as Current is correct, you may either enter the same address and press *, or just press * to return to
the reset menu. If you do not enter a new address, or enter the same address that is already assigned to this unit, you will
need to clear the memory separately (see “Clear the Controller’s RAM’’ on page 31).
NOTE: Changing the address of an EntraGuard Gold controller completely erases all information within the controller.
It is vitally important that you collect all data from the controller before changing the address. Once the address is
changed (and the RAM is automatically cleared) the information in the controller is lost and cannot be recovered.
If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The
number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been
entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown
as Current, the controller will automatically clear the memory as it changes the address (see Figure 36).
Figure 36: Clearing Memory
Once the memory has been cleared, the unit is ready to be configured. The LCD will display a warning that the unit has
not been initialized (see Figure 37 on page 30). This display will rotate with the EntraGuard Default display (see Figure
38 on page 30) until a Total Update from
Doors
has been performed on the unit. Once an update has been performed,
only the default will be displayed.