EntraGuard

®

 – Gold

Quick S

tart Guide

5.1.3

Shared Phone Line for Multiple EntraGuard Gold Units on a Network

A single phone line may be shared for communication between multiple EntraGuard Gold units and tenants. The phone 
line is plugged into either the J3 phone plug (using an RJ11 connector) or TB-15 on the Voice Channel and Input/Output 
board of the master EntraGuard Gold unit.

On controllers using an RJ11 phone plug, the phone line then goes out of the J4 phone plug to the next unit’s J3 plug and 
so on to all the networked EntraGuard units (see Figure 16). On all other controllers, the phone line connects from TB-
15 to the next unit’s TB-15 and so on to all the networked EntraGuard units (see 

NOTE: Sharing a phone line for multiple EntraGuard units is limited to a maximum of 6 units per phone line.

Figure 16: Single Phone Line for a Multiple EntraGuard Gold Unit Network Using RJ11 Phone Plugs

Summary of Contents for Gold

Page 1: ... instructions and short descriptions of key terms and concepts for installing the EntraGuard Gold Telephone Entry controller The EntraGuard Gold controller may be used alone or may be connected to a PXL network 1 NOTE It is the responsibility of the installation organization to have only technically qualified personnel performing the installation Figure 1 The EntraGuard Gold Telephone Entry Contro...

Page 2: ...kerisys com E mail sales kerisys com Page 2 of 32 Quick Start Guide EntraGuard Gold Figure 2 The EntraGuard Gold Telephone Entry Controller Alpha Numeric Keypad Front Panel NOTE Keri Systems Inc recommends routine maintenance on the EntraGuard Gold controller with the radiant alpha numeric keypad be performed by wiping down the red bezel surrounding the EntraGuard keypad ...

Page 3: ... of 32 EntraGuard Gold Quick Start Guide Figure 3 The Gold Telephone Entry Controller Main Board1 NOTE You must power down the unit before attempting to make or remove any connections Failure to do so will damage the controller 1 For all EntraGuard Gold controllers with the alpha numeric keypad and EntraGuard Gold controllers with the mechanical standard keypad with part numbers 05712 001 05712 00...

Page 4: ...2 Quick Start Guide EntraGuard Gold Figure 4 The Gold Controller Voice Channel and Input Output Board1 NOTE You must power down the unit before attempting to make or remove any connections Failure to do so will damage the controller 1 For all EntraGuard Gold controllers with the alpha numeric keypad and EntraGuard Gold controllers with the mechanical standard keypad with part numbers 05712 001 057...

Page 5: ...ail sales kerisys com Page 5 of 32 EntraGuard Gold Quick Start Guide Figure 5 The Gold Controller Voice Channel and Input Output Board1 NOTE You must power down the unit before attempting to make or remove any connections Failure to do so will damage the controller 1 For EntraGuard Gold controllers with the mechanical standard keypad with part numbers 05720 001 05720 002 and 05721 001 ...

Page 6: ...er supply as the EntraGuard Gold controller please ensure the power supply provides enough current to drive every device connected to that supply plus an adequate safety margin AC power cannot be used NOTE Isolation of power supplies may be required with high transient situations Controller Memory Retention 5 year lithium battery back up to support controller RAM and real time clock Output Relay C...

Page 7: ...ork configurations of up to 5 000 feet per star line and 16 000 feet total network length Telephone 1 pair copper phone line NOTE EntraGuard Gold is not to be used with a Centrex PBX or digital phone line Only use a Plain Old Telephone Service POTS analog phone line Input Power two conductor stranded AWG 18 wire Belden 8461 or a larger gauge NOTE On long power cable runs the cable resistance cause...

Page 8: ...ss electric devices attached to a controller output use an isolation relay P N IRP 1 if attaching to a parking gate a turnstile or any application using a large electric motor verify the controller s supply voltage is 12 VDC long power line runs cause a drop in voltage at the end of the run verify proper operation of the host computer s COM port or Ethernet LAN WAN connection DO NOT make modem pho...

Page 9: ... mail sales kerisys com Page 9 of 32 EntraGuard Gold Quick Start Guide 4 0 Wiring Instructions Refer to Figure 4 on page 4 for all wiring connections 4 1 Terminal Blocks Figure 6 Connecting Wires and Removing Terminal Blocks NOTE Screws on terminal blocks must be tightened securely 4 2 Connecting the Earth Ground and the 12 VDC Power Figure 7 Earth Ground and 12 VDC Power Connections ...

Page 10: ...h an installation kit including all necessary terminal blocks and transorbs One of these terminal blocks has a jumper across pins 1 and 2 This terminal block is designated for use on TB 4 If a door switch is not used on the controller this jumper prevents a continuous door open status alarm from being received by the controller If a door switch is used simply remove this jumper and install the doo...

Page 11: ...cess control software There are two possible uses for the general purpose input the master controller may be configured for either Global Unlock see Figure 10 or Auxiliary A door RTE see Figure 11 the slave unit1 can only be configured for Auxiliary A door RTE see Figure 11 Make the following connections for a Global Unlock input For a master controller only Figure 10 Global Unlock Input Connectio...

Page 12: ...A 800 260 5265 408 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 12 of 32 Quick Start Guide EntraGuard Gold 4 6 Connecting an Alarm Output Relay Figure 12 Alarm Output Relay Connections 4 7 Connecting a Fail Safe Lock Output Relay Figure 13 Fail Safe Lock Output Relay Connections ...

Page 13: ...1801 001 Rev 2 2 San Jose CA 95112 USA 800 260 5265 408 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 13 of 32 EntraGuard Gold Quick Start Guide 4 8 Connecting a Fail Secure Lock Output Relay Figure 14 Fail Secure Lock Output Relay Connections ...

Page 14: ...gure 4 on page 4 while others have a terminal block see TB 15 in Figure 5 on page 5 for use with a phone line If the EntraGuard Gold controller has a terminal block instead of an RJ11 plug connect the TIP line to either Pin 1 or Pin 2 then connect the Ring line to the other Pin see Figure 15 Figure 15 TB 15 Phone Line Wiring Connection There are three ways of connecting the phone line for communic...

Page 15: ...into either the J3 phone plug using an RJ11 connector or TB 15 on the Voice Channel and Input Output board of the master EntraGuard Gold unit On controllers using an RJ11 phone plug the phone line then goes out of the J4 phone plug to the next unit s J3 plug and so on to all the networked EntraGuard units see Figure 16 On all other controllers the phone line connects from TB 15 to the next unit s ...

Page 16: ...e 100 01801 001 Rev 2 2 San Jose CA 95112 USA 800 260 5265 408 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 16 of 32 Quick Start Guide EntraGuard Gold Figure 17 Single Phone Line for a Multiple EntraGuard Gold Unit Network Using TB 15 ...

Page 17: ... board see Figure 4 on page 4 or Figure 5 on page 5 NOTE If you are using two separate phone lines one for communication with the tenants and one for programming you will not be able to use the internal modem for programming and must use an external modem connected to the RS 232 as described in Section 5 2 2 2 on page 21 Once the phone line has been attached the JP3 jumper must be set for proper o...

Page 18: ... using the RS 232 serial port for communication NOTE Do not use male female gender changer plugs or 25 pin to 9 pin adapters when making RS 232 serial port connections These devices may have internal wiring changes that can disrupt communications when implemented in conjunction with the Keri Systems serial wiring instructions If you must use a gender changer plug ensure it is a straight through pl...

Page 19: ...e drawings in Figure 19 or Figure 20 If the host computer has a male DB 25 connector on the serial port you must use a Keri Systems KDP 251 cable or create a cable according to the drawing in Figure 21 on page 20 or Figure 22 on page 20 The Keri Systems part number for this cable is KDP 252 Figure 19 PC DB 9F to Telephone Entry DB 9M RS 232 Direct Serial Connections1 Figure 20 PC DB 9F to Telephon...

Page 20: ... this cable is KDP 251 Figure 21 PC DB 25F to Telephone Entry DB 9M RS 232 Direct Serial Connections1 Figure 22 PC DB 25F to Telephone Entry TB 12 RS 232 Direct Serial Connections2 1 For all EntraGuard Gold controllers with the alpha numeric keypad and EntraGuard Gold controllers with the mechanical standard keypad with part numbers 05712 001 05712 002 and 05713 001 2 For EntraGuard Gold controlle...

Page 21: ...as a female DB 25 connector you must use a Keri Systems KDP 336 cable or create a cable as shown in Figure 23 or Figure 24 If the modem has a female DB 9 connector you must create a cable as shown in Figure 25 or Figure 26 on page 22 If the modem was purchased from Keri Systems it comes with an adapter that accommodates a female DB 9 connector should the modem have a DB 9 instead of a DB 25 connec...

Page 22: ...65 408 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 22 of 32 Quick Start Guide EntraGuard Gold The Keri Systems part number for this cable is KDP 929M Figure 25 Modem DB 9M to Telephone Entry DB 9M Serial Port Connection Figure 26 Modem DB 9M to Telephone Entry TB 12 Serial Port Connection ...

Page 23: ...isys com E mail sales kerisys com Page 23 of 32 EntraGuard Gold Quick Start Guide 5 2 2 3 Modem Cable Connection An adapter cable is provided when needed with a modem purchased from Keri Systems Connect the adapter cable between the modem and the KDP 336 cable as shown in side A of Figure 27 To use the KDP 929M cable see side B of Figure 27 Figure 27 Modem Cable Connection ...

Page 24: ...erial port has a female DB 25 connector purchase or create a cable as shown in Figure 29 If the modem has a male DB 9 connector and the host computer s serial port has a female DB 9 connector purchase or create a cable as shown in Figure 30 on page 25 If the modem has a male DB 9 connector and the host computer s serial port has a female DB 25 connector purchase or create a cable as shown in Figur...

Page 25: ...2 San Jose CA 95112 USA 800 260 5265 408 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 25 of 32 EntraGuard Gold Quick Start Guide Figure 30 Modem DB 9M to PC DB 9F PC Serial COM Port Connection Figure 31 Modem DB 9M to PC DB 25F PC Serial COM Port Connection ...

Page 26: ...8 451 2520 FAX 408 441 0309 Web http www kerisys com E mail sales kerisys com Page 26 of 32 Quick Start Guide EntraGuard Gold 5 3 Network Communication 5 3 1 RS 485 Access Control Network Connection The following figure shows how to connect more than one controller to the access control network Figure 32 RS 485 Network Connections ...

Page 27: ...local US Postal Service to arrange for the installation of a postal lock into the EntraGuard Gold controller 1 Remove the hole plug on the faceplate of the EntraGuard Gold unit 2 Remove the two hex nuts from the postal lock mounting studs Mount the postal lock on the two studs and secure with the hex nuts Figure 33 Postal Lock Installation When the lock is installed check to be sure that the pawl ...

Page 28: ...verify the cable gauge is AWG 18 NOTE On long power cable runs keep in mind the resistance in the cable itself causes a drop in voltage at the end of the run The power supply must be able to account for this voltage drop 8 0 Setup Controller If you re turning system power on for the first time certain tasks must be performed prior to entering access control information from Doors On the EntraGuard...

Page 29: ...u do not enter a new address or enter the same address that is already assigned to this unit you will need to clear the memory separately see Clear the Controller s RAM on page 31 NOTE Changing the address of an EntraGuard Gold controller completely erases all information within the controller It is vitally important that you collect all data from the controller before changing the address Once th...

Page 30: ... slave controllers on the access control network can identify the master controller For the Master Controller to correctly identify all slave controllers on the network one of two things must be done 1 The master controller must be the last unit on the network to be powered on This ensures that when the Master Controller begins polling the network to see what slave units are connected for system c...

Page 31: ...M has been cleared the unit is ready for use The LCD will rotate between the Initialization Warning and EntraGuard Default screens see Figure 37 on page 30 and Figure 38 on page 30 until a Total Update from Doors has been performed on the unit or 2 Press 2 to return to the Reset Menu without clearing the controller s RAM NOTE Clearing the system RAM completely erases all information within the Ent...

Page 32: ...o one there pressing the button the switch remains open When someone desires to exit through a secure door they press the RTE button closing the circuit and generating a state change The controller then responds to this state change and generates an output such as unlocking the door to allow egress 10 0 General Information on Safety versus Security with Door Locks When installing a door lock there...

Reviews: