Uninterruptible Power Supply (UPS)
B-2
Figure B-1. Connecting the SM Module to a UPS
Configuring COM Port for UPS
After the UPS has been connected to the COM2 port, the COM2 port must be
conÞgured for UPS Management. To conÞgure the COM2 port for UPS
Management, follow the steps below.
1. Connect the terminal or PC used for local management to the COM1 port on
the System Monitor (SM) and press RETURN until the Slot Selection Screen
displays.
2. At the Slot Selection Screen, enter 0 (zero) to display the SM ConÞguration
Screen.
3. At the SM ConÞguration Screen, cursor to the Application Field for the COM2
port.
4. Using the SPACE bar, toggle to the
UPS
option.
5. Using the arrow key, highlight the
SAVE
option and press RETURN.
If you need additional information about conÞguring the COM ports, refer to the
SmartSwitch 9000-6 Slot Module Local Management UserÕs Guide.
9-Pin D Connector Receptacle
9C306 Module (Front View)
Matrix UPS (Back View)
STATUS
SM
9C306
C
O
M
1
C
O
M
2
EPIM
LNK
EPIM-T
COM2 Port