2-1
Chapter 2
Installing the 9C306 System Monitor
The 9C306 System Monitor is installed in the slot marked SM at the right front
side of the SmartSwitch 9000-6 Slot chassis, as shown in Figure 2-1.
Install a System Monitor by following the steps below:
1. Unpack the System Monitor Module by removing it from the shipping box
and sliding the two foam end caps off the unit. (Save the shipping box and
packing materials in the event the System Monitor must be reshipped.)
2. Remove the System Monitor Module from the protective plastic bag. Observe
all precautions to prevent damage from Electrostatic Discharge (ESD). (Save
the bag in the event the System Monitor must be reshipped.)
3. Remove the plastic protective cap that covers the connector on the rear of the
System Monitor Module.
4. Examine it carefully, checking for damage. If any damage exists, DO NOT
install it. Immediately contact Cabletron Systems for Technical Support.
5. Install the System Monitor Module in the chassis slot marked SM, as shown in
Figure 2-1. Slide the module between the module guides. Take care that the
module slides in straight and properly engages the backplane connectors.
Lock down the plastic tabs at the top and bottom of the module.
If the SmartSwitch 9000-6 Slot chassis has been powered up, the 9C306 System
Monitor illuminates the STATUS LED.
If the Status LED is any color other than green, refer to Chapter 3 for a description
of the status.
!
CAUTION
Before handling the System Monitor Module or any SmartSwitch 9000 Interface
Modules, attach the ESD (Electrostatic Discharge) Wrist Strap. Then observe all
static safety precautions to prevent damage from ESD when handling the
modules.