B-1
Appendix B
Uninterruptible Power Supply (UPS)
Introduction
The SmartSwitch 9000-6 Slot can be connected to a UPS to provide an
uninterruptible source of AC power. Two UPS models are available, the Matrix
3000 and the Matrix 5000. Either can be monitored via remote SNMP
Management after connecting the UPS to the System Monitor (SM) module.
Connecting a UPS to the System Monitor Module
To connect a UPS to a System Monitor Module, use the RJ45/DB9 adapter and the
RJ45 cable included in the cable kit shipped with the System Monitor Module,
and follow the steps below.
1. Plug one end of the RJ45 cable into the RJ45/DB9 adapter labeled UPS.
2. Connect the DB9 connector of the UPS adapter into the DB9 receptacle on the
UPS unit. See Figure B-1.
3. Connect the free end of the RJ45 cable into the COM2 port on the front of the
System Monitor Module. See Figure B-1.
Summary of Contents for 9C306
Page 1: ...9031994 01 SmartSwitch 9000 6 Slot 9C306 System Monitor User s Guide...
Page 2: ......
Page 6: ...Notice iv...
Page 8: ...Contents vi...