background image

ENG

Ensto One Home

RAK131_ENG

6.4.2021

© 2020 Ensto

Installation Manual

Summary of Contents for One Home

Page 1: ...ENG Ensto One Home RAK131_ENG 6 4 2021 2020 Ensto Installation Manual...

Page 2: ...VH163 HC000 EVH323 HC000 internal circuit example 18 10 EVH161 HCR00 EVH321 HCR00 internal circuit example 19 11 EVH163 HCR00 EVH323 HCR00 internal circuit example 20 12 Dimension drawing 21 13 Troubl...

Page 3: ...empts the installer or user from responsibility to follow all applicable safety regulations This Installation Manual is a part of the product and must be stored in a safe location so that it is availa...

Page 4: ...ove the charger from its package Do not scratch the surface of the charger after removal from the package When selecting installation site take into account the following The charger is suitable for i...

Page 5: ...the bottom of the charger If you need to open additional cable entries you have to disassemble the charger Installation steps when cable routing is from alternative cable entries 1 Disassemble the ch...

Page 6: ...t for cable 8 17mm RMM32B Membrane gasket for cable 12 24mm 2 Open the needed cable entries with a step drill bit 3 Prepare the cable entries with suitable accessories 4 Remove the included cable glan...

Page 7: ...erial suitable screws 2 Fasten the upper screw 1270 mm measured from the ground surface The plug holder will be at a height of 1200 mm 3 3 Wall mounting When selecting the installation location make s...

Page 8: ...tening screws not included 3 Be careful not to damage the fixed charging cable 7 Pull the electrical cables approx 150mm through the cable glands 8 Cut the supply cable leads in suitable lengths Leave...

Page 9: ...charger accordingly You can change the setting with the Ensto Charger Control Application Please see the chapter 14 Ensto Charger Control Application on pages 22 23 EVH161 HC000 EVH321 HC000 Install...

Page 10: ...RCD type A 30mA and a circuit breaker MCB max 16A or max 32A depending on charger model to the supply line In addition follow local regu lations for the power supply line Do not connect these charger...

Page 11: ...it breaker and over current protection RCBO is integrated A label set of RCBO testing instructions is included in the delivery Attach a language spe cific label on the installation box hatch Do not co...

Page 12: ...ted A label set of RCBO testing instructions is included in the delivery Attach a language spe cific label on the installation box hatch Connect these charger models to a 3 phase supply otherwise the...

Page 13: ...HC000 EVH161 HCR00 EVH163 HCR00 EVH321 HCR00 EVH323 HCR00 Material Polycarbonate Color Frame RAL7021 dark grey Cover Silver Installation box Screw fixing Mechanical hatch lock Weight approx 7 kg Ingr...

Page 14: ...ge detection integrated RDC DD 6mA RCD type A 30mA must be in stalled in distribution board Leakage detection integrated RDC DD 6mA Residual current circuit breaker and over current protection integra...

Page 15: ...ble D Domestic socket Not available M MID class kWH meter Not available R RCBO Fixed charging cable 2 Type 2 socket T2 S Type 2 Shutter socket T2S Home A Apartment 1 phase 3 3 phase Max charging curre...

Page 16: ...allation site Electrical installation Charger s power supply capacity meets electrical planning cable size protective devices Review the local electrical design plan The the PE cable screw is tight Th...

Page 17: ...mple LED Board A1 EVI200 x1 C1 PE PE N L1 CP L1 N J1 J4 J3 J8 J16 J6 J7 J6 J1 J16 J8 J4 J5 J7 J3 L1 L1 N N Note All signal wires must be at a sufficient distance from the power wires or protected with...

Page 18: ...24 9 EVH163 HC000 EVH323 HC000 internal circuit example Note All signal wires must be at a sufficient distance from the power wires or protected with insulating shield plastic spiral Supply Cu 2 5 10...

Page 19: ...LED Board x1 C1 PE N L1 CP J1 J4 J3 J8 J16 J6 J7 J4 L N QF1 L N L N L N PE A1 EVI200 J6 J1 J16 J8 J4 J5 J7 J3 Note All signal wires must be at a sufficient distance from the power wires or protected...

Page 20: ...4 11 EVH163 HCR00 EVH323 HCR00 internal circuit example Note All signal wires must be at a sufficient distance from the power wires or protected with insulating shield plastic spiral Supply Cu 2 5 10...

Page 21: ...s off no lights on Issue Corrective action Mains voltage does not exist in supply connectors L1 L2 L3 Ensure proper power supply The circuit breaker QF1 is off EVH HCR00 Turn the QF1 on 12 Dimension d...

Page 22: ...pleted You can control the charger and change settings with the Ensto Charger Control Applica tion In this chapter is described the installer menu in the application For additional instructions please...

Page 23: ...enu 14 1 5 Phase rotation only 3 phase chargers Selection of phase rotation is only informative and does not affect the charger operation 14 1 6 Eathing System The default setting for power supply is...

Page 24: ...e n s t o c o m Ensto Chago Oy Ensio Miettisen katu 2 P O Box 77 FIN 06101 Porvoo Finland Tel 358 204 76 21...