RAK131B_ENG / 2022-10-14
11 / 24
EVH163B-HC000 / EVH323B-HC000:
•
Install a residual current device (RCD type A, 30mA) and a circuit
breaker (MCB max. 16A or max. 32A depending on charging
station model) to the supply line. In addition obey local regula-
tions for the power supply line.
•
Do not connect these charging station models to an IT network.
L1 L2 L3
L1
N
PE
EVH161B-HCR00 / EVH321B-HCR00:
•
A combined device with residual current circuit breaker and over
current protection (RCBO) is integrated.
•
A label set of RCBO testing instructions is included in the delivery.
Attach a language specific label on the installation box hatch.
•
Do not connect these charging station models to an IT network.
L
N
PE
L
N
QF1
PE L1 L2 L3 N
Supply
Cu 2.5 - 10 mm²
PE
L
N
TN network
Supply
Cu 2.5 - 10 mm²
TN network