The set value of the floor temperature is adjusted by rotating adjusting wheel with a screwdriver (Fig.
3). The heating is switched on when the temperature measured by the sensor is lower than the set
value of the thermostat.
•
The fixed temperature reduction (-5°C) of the thermostat affects the temperature setting of the floor
directly.
•
The correspondence between the set value and the temperature of the floor is described in Table 1.
Table 1
Set value
Floor temperature (ºC)
0
5
1
14
2
22
3
30
4
40
5
50
4. TECHNICAL DATA
Supply voltage:
230 V /50 Hz, -15% / +10%
Adjustment range:
5 - 50 °C
Load (max):
3600W, 16A cos
ϕ
= 1 / 2A cos
ϕ
= 0,4
Operating temperature range: -30...+30 °C’
Temperature reduction:
fixed –5 °C, control 230V
Floor-sensor:
NTC, 47 kΩ at 25°C, cable 4 m (extendable up to 25 m)
Circuit fuse:
16A
Protection class:
IP20
1. SISSEJUHATUS
ECO16FD on põrandatermostaat paigaldusega DIN-liistule.
Seadmel ei ole lülitit, kuid see tuleb kindlasti ahelasse eraldi paigaldada. Põrandaküte peab olema ühen-
datud läbi rikkevoolukaitse.
2. PAIGALDAMINE
•
Kinnita põrandatermostaat Din-liistule nii nagu on näidatud Joonisel 1. Vaata ühendusskeemi Joo-
nisel 2.
•
Ühenda temperatuurialandus termostaadi klemmile ‘T-’. Temperatuurialandus hakkab tööle välise
pinge lülitamisel ükskõik millisest faasist antud klemmile.
•
Kontrolli, et juhitav küttevõimsus ei ületa termostaadile lubatavat nimikoormust. Kontrolli termos-
taadi poolt juhitava kütteahela takistust ja küttekaabli isolatsioonitakistust.
•
Paigalda anduri kaabel kaitsetorusse kahe kaabliahela vahele.
MÄRKUS! Veendu, et kaitsetorus po-
leks vett.
NB! Lülita toitepinge välja enne paigaldust või hooldust. Käesolev paigaldusjuhend tuleb alles hoida või-
malikke hooldustöid silmas pidades.
EST