12. Technical Data
Supply voltage
230 V -15%, +10%, 50 Hz
Switch
Not on the device, a separate main switch
must be installed
Rated current
16 A
Maximum load
3600 W
Operating temperature range
-20 ... +30 °C
Thermostat adjustment range
5 ... 35 °C room
5 ... 50 °C floor
Floor max. limitation range
+25 … +50 °C
Floor min. limitation range
+5 … +40 °C
Floor sensor
NTC, 47 kΩ/25°C, cable 4 m
(extendable to 25 m)
Sensor resistance values
Table 1, on page 2 (sensor not connected)
Fuse
Max. 16 A
Ingress Protection
IP20
Pollution degree rating
2
Rated impulse voltage
4 kV
Power in standby
< 0,5 W
Radio frequency range
2,4 ... 2,483 GHz
Radio max. power
+3 dBm
Dimensions WxHxD
36 x 90 x 58 mm
13. Accessories
ECOAC2
Room sensor: NTC, 47 kΩ/25°C, cable 4m
(extendable to
25
m)
LS994BWWFI
Blank centre plate, white
LS981WW85FI
Cover frame, 85mm, white