41
F4
Cooling system gas flow abnormal PROTECTION.. Please check the troubleshooting for detail.
F5
PFC PROTECTION
Please check the troubleshooting for detail.
F6
The Compressor lack of phase / Anti-phase
PROTECTION.
Please check the troubleshooting for detail.
F7
IPM Module temperature PROTECTION
Please check the troubleshooting for detail.
F8
4-Way Value reversing abnormal..
Please check the troubleshooting for detail.
F9
The module temperature test circuit failure.
ODU PCB
FA
The compressor Phase-current test circuit failure.
ODU PCB
Fb
Limiting/Reducing frequency for Over load
protection on Cooling/Heating mode.
Querying by press remote controller
FC
Limiting/Reducing frequency for High power
consumption protection.
Querying by press remote controller
FE
Limiting/Reducing frequency for Module current
protection ( phase current of compressor).
Querying by press remote controller
FF
Limiting/Reducing frequency for Module
temperature protection.
Querying by press remote controller
FH
Limiting/Reducing frequency for Compressor
driving protection.
Querying by press remote controller
FP
Limiting/Reducing frequency for anti-condensation
protection..
Querying by press remote controller
FU
Limiting/Reducing frequency for anti-frost
protection.
Querying by press remote controller
Fj
Limiting/Reducing frequency for Discharge over
temperature protection.
Querying by press remote controller
Fn
Limiting/Reducing frequency for ODU AC Current
protection.
Querying by press remote controller
Fy
Gas leakage protection
Please check the troubleshooting for detail.
bf
TVOC sensor failure
(
IDU failure, optional
)
Querying by press remote controller
bc
PM2.5 sensor failure
(
IDU failure, optional
)
Querying by press remote controller
bj
Humidity sensor failure.
(
IDU failure
)
Querying by press remote controller
Note: Remote controller FAILURE CODE Querying function
As shown in the failure codes, some of the codes (Fb~bj) need to press remote control for inspection.
While unit on operation, press the ECO button 8 times with
in
8 seconds, the buzzer BIBI 2 times, you can
inspect the special failure code as Fb ~Fn, bj etc.