Use the
FrmSync
menu shown below to set the following parameters:
•
Frame Sync
– turn the frame synchronizer function on or off. When on, the output
stream will be timed with the selected reference signal.
•
Hor Timing –
set the amount of horizontal timing in clocks.
•
Ver Timing
– set the amount of vertical timing in lines.
The total amount of delay through the module in lines will be reported in the
Delay
display. This value may be used in conjunction with other modules to match required
delays.
Model 5450 Digital Video Frame Synchronizer
5450-15