![Enraf Tanksystem HERMetic UTImeter Rtex Operation And Service Manual Download Page 22](http://html1.mh-extra.com/html/enraf-tanksystem/hermetic-utimeter-rtex/hermetic-utimeter-rtex_operation-and-service-manual_2414103022.webp)
50455/RTEX/0807
UTImeter Rtex
22
7.3 Example of installation on the deck, connector Q2
Tank Zero Ullage level
Flange
H
Reading
index
474mm
HV
HX
Tank Deck
SS1 Q2
Flange
Reading
index
474mm
HV
HX
SS2 Q2
Figure 7-3
Valve designation
C.2-SS; C.2-SS-W; C.2-SS-BL; C.2-SS-SEC
Bottom connection
thread or flange
Boring
2”
*) HV (mm)
141
*) HX (mm)
H-615
*) Dimension HV is without gasket. If gaskets are used dimension HX is reduced by thickness of gasket.