background image

PIONEER

 SPECIFICATIONS

PIONEER

NAME AND

PART NUMBER

PEAK FLOW & 

% REDUCTION

OF LEAD

CHLORINE/CHLORAMINE TASTE

AND ODOR REDUCTION CAPACITY (*)

PRESSURE

DROP

SPEC

 PIONEER

System

 

CTA0840BBBKP5-04C00

REPLACEMENT CARTRIDGE FILTERS ARE LISTED AS PIONEER™ 0.5 Micron High Capacity Carbon Block   //  PART NUMBER: 

CT-05-CB-AMYCL

9 psid

@ 4.51 GPM

8 GPM (30.2lpm) @ 

99.62%  reduction                                     

(*) >88,000 gallons 

at 8 GPM (333,116 

Liters @ 30.2lpm)

>300,000 gallons @ 15 GPM (1,135,533 Liters @ 56.8 lpm) 

with greater than 90% reduction, estimated capacity using 

2ppm of free chlorine.

>150,000 gallons @ 8 GPM (567,812 Liters @ 30.3 lpm) 

with greater than 85% reduction, estmated using 3ppm 

of chloramine.

*Claims are not performance tested by IAPMO or NSF. Performance claims are based on independent laboratory and manufacturer’s internal test data. 

Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary. 

Model Number of the system in which the filter component is to be used with CTA0840BBBKP5-04C00

SIZE &  

MICRON 

RATING

RATED CAPACITY

& FLOW RATE

8” x 40”

0.5

Lead Reduction and PFOA/PFOS

100,000 gallons @ 4.51 GPM

(378,541 Liters @ 17.1 lpm) 

@ 99.62% lead reduction 

@ 97.9% PFOA/PFOS reduction

ENPRESS®, ONE

®

, WATER FILTRATION SIMPLIFIED

®

 AND PIONEER™ are trademarks of ENPRESS, LLC.

© ENPRESS LLC 2018  |  PIONEER

 is an ENPRESS Filtration Technology  |  2019-0103

If you have any questions regarding your water filter, contact your local dealer, OEM, or the manufacturer at the following:

For more information, visit enpress.com or onefiltration.com

THANK YOU FOR CHOOSING PIONEER

POWERED BY

Where Innovation Flows

PERFORMANCE

Performance claims are based on independent lab results 

and manufacturer’s internal test data*. Actual performance is 

dependent on influent water quality, flow rates, system design 

and applications. Your results may vary. Performance claims 

are based on a complete system, including a filter, housing, 

and connection to a pressurized water source. This filter must 

be operated according to the system’s specifications in order 

to deliver the claimed performance. It is essential to follow 

operational, maintenance, and filter replacement requirements, 

as directed for each application, for this filter and system to 

perform correctly. Read the Manufacturer’s Performance 

Data Sheet accompanying the system and change the filter as 

suggested. The contaminants or other substances removed or 

reduced by this water filter are not necessarily in all users’ water.

IMPORTANT

DO NOT USE

 extra lubricants, unapproved sealants and tools 

to  tighten hand tightened only parts. Use of tools other than 

hand tighten only parts voids warranty. Testing was performed 

under standard laboratory conditions; actual performance may 

vary. Flush the system and change the filter as suggested. The 

contaminants or other substances removed or reduced by this 

water filter are not necessarily in all users’ water.

WARRANTY

LIMITED LIABILITY

 - ENPRESS LLC makes no warranties of any 

kind, expressed or implied, statutory or otherwise, and expressly 

disclaims all warranties of every kind, concerning the product, 

including, without limitation, warranties of merchantability and 

fitness for a particular purpose, except that this product should be 

capable of performing as described in this product’s data sheet. 

ENPRESS LLC’s obligation shall be limited solely to the refund 

of the purchase price or replacement of the product proven 

defective, in ENPRESS LLC’s sole discretion. Determination of 

suitability of this product for uses and applications contemplated 

by Buyer shall be the sole responsibility of Buyer. Use of this 

product constitutes Buyer’s acceptance of this Limited Liability. 

CERTIFICATIONS

MANUFACTURED BY

This ENPRESS pressure vessel 

is tested and certified by NSF 

International against NSF/ANSI 

Standard 44 and 61 for materials and 

structural integrity requirements

COMPONENT

EPA Est. 092577-OH-001

ENPRESS, LLC.  |  34899 Curtis Blvd., Eastlake Ohio 44095  |  Phone 866.859.9274  |  Fax 440.510.0202  |  [email protected]

SUBSTANCE

INFLUENT CHALLENGE 

CONCENTRATION 

(MG/L)

MAXIMUM PERMISSIBLE 

PRODUCT WATER 

CONCENTRATION (MG/L)

Lead

Cyst

PFOA/PFOS

0.15 +/- 10%

minimum 50,000/L

1.5 +/- 10%

0.01

  99.95%

0.07

Minimum Operating Temperature

 

34 F / 1 C

Maximum Operating Temperature:

 

120 F / 50 C

Minimum Operating Pressure:

 

20 psig / 1.38 bar

Maximum Operating Pressure:

 

125 psig / 8.6 bar

Electrical Requirements:

  Grounded & Unswitched 115 V outlet and 

3-AAA Batteries

Filter Replacement Operating Instructions:

 New cartridges must be 

flushed for a minimum of 10 minutes prior to use. System and installation 
to comply with state and local laws and regulations.

Do not

 use with water that is microbiologically unsafe or unknown

quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters 
that may contain filterable cysts.
Manufactured from NSF/ANSI standard 61 and California Prop 65
Compliant certified coconut shell carbon and raw materials.

NSF/ANSI

STANDARD

53  
53

P473

This ENPRESS system is certified 

by IAPMO R&T against NSF/ANSI  

Standards 53 and P473 (also CSA 

B483.1) for the reduction of claims 

specified on the performance 

data sheet.

This system has been tested for the reduction of the 

substances listed below. The concentration of the indicated 

substances in water entering the system was reduced to 

a concentration less than equal to the permissible limit for 

water leaving the system, as specified in NSF/ANSI 53 and 

P473. Minimum substance reductions are as follows:

Summary of Contents for CTA0840BBBKP5-04C00

Page 1: ......

Page 2: ... V WATER SUP P LIES _ _ SOURCE https Www cnn com 2016 06 28 us apa lead in u s wat r systems index html 1 IIGO l OQO lt 000 14 o IOMIOO 11 M 1 00UOO PIONEER SUCCESSFULLY REMOVES LEAD Not only does PIONEER remove heavy metals such as lead it also removes and or reduces chlorine chloramine and other harmful contaminants in your water including 99 95 of Cysts Microbial Cysts like Giardia and Cryptosp...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...e to the chemicals may lead to cancer PIONEER successfully removes these chemicals and is installed where the water line enters your home business or restaurant This system has been tested and third party certified as required in the NSF ANSI P473 standard for PFOA PFOS along with NSF ANSI 53 standard for the reduction of lead and cyst PIONEER is the First of its Kind Whole House Lead Cyst PFOA PF...

Page 8: ...Americans have at least some level of chemicals in their blood and has been found in water supplies across more than 27 states It s obvious that PFOA PFOS chemicals need to be removed from your water The PIONEER POE filtration system houses a strategically designed nominal 0 5 micron filter to remove BOTH chemicals along with BOTH forms of lead soluble and particulate from your house in a single f...

Page 9: ...future reference If you have any questions regarding your water filter contact your local dealer OEM or the manufacturer at the following ENPRESS LLC 34899 Curtis Blvd Eastlake Ohio 44095 Phone 866 859 9274 Fax 440 510 0202 info enpress com EPA Est 092577 OH 001 ...

Page 10: ... groove 7 Remove the top cap of the system by lifting up on the top handles remove old filter 8 Open the John Guest fitting and shut off and flush out the bottom of the system 9 Look down into the tank assembly and you should see a small opening centered in the bottom of the tank 10 Remove packaging from the new filter place the new cartridge into the tank with the double o ring facing down 11 Pos...

Page 11: ...ng of the same material as the existing plumbing or a grounded jumper wire bridging the equipment and reestablishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use DO NOT USE extra lubricants unapproved sealants and tools to tighten hand tightened only parts Use of tools other than hand tighten only parts voids warranty Testing was performed und...

Page 12: ...ment cartridge Service trips to installation site to train user on how to use product Improper installation Failure of product if it is abused misused or used for other than the intended purpose Replacement of water filter cartridge due to water pressure that is outside the specified operating range or due to excessive sediment in water supply or replacement with non authorized replacement cartrid...

Page 13: ...t the prior written consent of ENPRESS LLC Copyright 2018 ENPRESS LLC All rights reserved ENPRESS LLC 2018 PIONEER is an ENPRESS Filtration Technology 2019 0103 ENPRESS ONE WATER FILTRATION SIMPLIFIED AND PIONEER are trademarks of ENPRESS LLC For more information visit enpress com or onefiltration com POWERED BY Where Innovation Flows This ENPRESS pressure vessel is tested and certified by NSF Int...

Page 14: ...nder standard laboratory conditions actual performance may vary Flush the system and change the filter as suggested The contaminants or other substances removed or reduced by this water filter are not necessarily in all users water WARRANTY LIMITED LIABILITY ENPRESS LLC makes no warranties of any kind expressed or implied statutory or otherwise and expressly disclaims all warranties of every kind ...

Page 15: ...he Top Cap to seat o rings 15 If completed Step 2 then Close the John Guest fitting and shut off 16 Turn the water supply on opening the inlet and outlet valves on the bypass 17 Relieve the system of air in the tank as the system fills with water by pushing down on the red depressurization button on the top cap of the system Keep the button pushed down until all the air pressure is completely rele...

Page 16: ...n of IAPMO Research and Testing Inc Any alteration of this certificate could be grounds for revocation of the listing This document shall be reproduced in its entirety This certificate is not evidence of current listing To verify listing status visit the IAPMO R T Product Listing Directory at pld iapmo org Effective Date April 2019 Void After April 2024 Product Water Treatment Product Health Effec...

Page 17: ...ns Products listed on this certificate have been tested by an IAPMO R T recognized laboratory This recognition has been granted based upon the laboratory s compliance to the applicable requirements of ISO IEC 17025 Products are in compliance with the following code s Uniform Plumbing Code UPC Products are in compliance with the following standard s NSF ANSI 53 2017 ...

Page 18: ...106 750 4 82 Lead Cyst 1 xx can be any combination of numbers and letters and references the outer tank color yyy can be any combination of numbers and letters and references an internal designation not related to certification Page 3 of 3 This certificate is not evidence of current listing To verify listing status visit the IAPMO R T Product Listing Directory at pld iapmo org Void After April 202...

Page 19: ... made only by specific written permission of IAPMO Research and Testing Inc Any alteration of this certificate could be grounds for revocation of the listing This document shall be reproduced in its entirety The most updated information on this Certificate of Listing is available online at pld iapmo org Effective Date January 2019 Void After January 2020 Product Drinking Water Treatment Units PFOA...

Page 20: ...To Enpress Llc Products listed on this certificate have been tested by an IAPMO R T recognized laboratory This recognition has been granted based upon the laboratory s compliance to the applicable requirements of ISO IEC 17025 Products are in compliance with the following standard s NSF P473 2016 ...

Page 21: ...y CTA0838BBxxP5 04Cyyy 1 CT 05 CB AMCYL 38 93 250 4 21 PFOA PFOS CTA0840BBxxP5 04Cyyy 1 CT 05 CB AMCYL 100 000 4 51 PFOA PFOS CTA0842BBxxP5 04Cyyy 1 CT 05 CB AMCYL 42 106 750 4 82 PFOA PFOS Page 3 of 3 Void After January 2020 Product Drinking Water Treatment Units PFOA PFOS File No W 11467 Issued To Enpress Llc ...

Page 22: ...alendar year 2018 Under this registration you have the following responsibilities 1 Annual renewal of the registration for the next calendar year We will send a renewal notice in the first quarter of each year 2 Providing SWRCB with an updated Product Data Sheet PDS if there are any contaminant reduction claims that are dropped or other significant changes in the PDS 3 Informing SWRCB immediately ...

Page 23: ...rers or their representative to ensure that the registration remains current Please contact at WB DWP WTDevices WTDevices waterboards ca gov with any questions Sincerely Mark J Bartson P E Chief Technical Operations Section Supervising Engineer ...

Page 24: ...019 The registration must be renewed between March 1 and May 31 2019 Attached is a copy of the registration summary listing the model name model number trade names under which the system is sold health related contaminants claimed to be reduced and the date of initial registration Please let me know if there are any errors You are required to notify the department if you plan to make any changes i...

Page 25: ... Registration Date 05 24 2018 Last Fiscal Renewal Year Model Number CTA0840BBxxP5 04Cyyy Model Name PIONEER System Other Trade Names Date of Protocol Approval and Health Related Contaminants Claimed to be Reduced 05 25 2018 cysts 05 25 2018 lead Iowa Department of Public Health 5 29 2018 10 05 07 AM ...

Reviews: